The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
The channel architecture of aquaporin 0 at a 2.2-Å resolution
Open accessAbstract
We determined the x-ray structure of bovine aquaporin 0 (AQP0) to a resolution of 2.2 Å. The structure of this eukaryotic, integral membrane protein suggests that the selectivity of AQP0 for water transport is based on the identity and location of signature amino acid residues that are hallmarks of the water-selective arm of the AQP family of proteins. Furthermore, the channel lumen is narrowed only by two, quasi-2-fold related tyrosine side chains that might account for reduced water conductance relative to other AQPs. The channel is functionally open to the passage of water because there are eight discreet water molecules within the channel. Comparison of this structure with the recent electron-diffraction structure of the junctional form of sheep AQP0 at pH 6.0 that was interpreted as closed shows no global change in the structure of AQP0 and only small changes in side-chain positions. We observed no structural change to the channel or the molecule as a whole at pH 10, which could be interpreted as the postulated pH-gating mechanism of AQP0-mediated water transport at pH >6.5. Contrary to the electron-diffraction structure, the comparison shows no evidence of channel gating induced by association of the extracellular domains of AQP0 at pH 6.0. Our structure aids the analysis of the interaction of the extracellular domains and the possibility of a cell–cell adhesion role for AQP0. In addition, our structure illustrates the basis for formation of certain types of cataracts that are the result of mutations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[20] Processing of X-ray diffraction data collected in oscillation mode
Otwinowski, Z., & Minor, W. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)76066-x · Cited by 33,475
Crystallography & NMR System: A New Software Suite for Macromolecular Structure Determination
Brünger, A. T., Adams, P. D., Clore, G. M., DeLano, W. L., Gros, P., Grosse-Kunstleve, R. W., Jiang, J. S., Kuszewski, J., Nilges, M., Pannu, N. S., et al. (1998) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444998003254 · Cited by 15,715
HOLE: A program for the analysis of the pore dimensions of ion channel structural models
Smart, O. S., Neduvelil, J. G., Wang, X., Wallace, B. A., & Sansom, M. S. P. (1996) · Journal of Molecular Graphics · doi:10.1016/s0263-7855(97)00009-x · Cited by 1,793
Structural basis of water-specific transport through the AQP1 water channel
Sui, H., Han, B.-G., Lee, J. K., Walian, P., & Jap, B. K. (2001) · Nature · doi:10.1038/414872a · Cited by 1,166
Structure of a Glycerol-Conducting Channel and the Basis for Its Selectivity
Fu, D., Libson, A., Miercke, L. J. W., Weitzman, C., Nollert, P., Krucinski, J., & Stroud, R. M. (2000) · Science · doi:10.1126/science.290.5491.481 · Cited by 1,000
Self-citationMAB, a generally applicable molecular force field for structure modelling in medicinal chemistry
Gerber, P. R., & M�ller, K. (1995) · Journal of Computer-Aided Molecular Design · doi:10.1007/bf00124456 · Cited by 593
Yang, B., & Verkman, A. S. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.26.16140 · Cited by 393
Aquaporin-0 membrane junctions reveal the structure of a closed water pore
Gonen, T., Sliz, P., Kistler, J., Cheng, Y., & Walz, T. (2004) · Nature · doi:10.1038/nature02503 · Cited by 389
Phylogenetic Characterization of the MIP Family of Transmembrane Channel Proteins
Park, J. H., & Jr., M. H. S. (1996) · Journal of Membrane Biology · doi:10.1007/s002329900120 · Cited by 312
Architecture and Selectivity in Aquaporins: 2.5 Å X-Ray Structure of Aquaporin Z
Savage, D. F., Egea, P. F., Robles-Colmenares, Y., III, J. D. O., & Stroud, R. M. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000072 · Cited by 300
Self-citation
Cited by
Structural mechanism of plant aquaporin gating
Törnroth-Horsefield, S., Wang, Y., Hedfalk, K., Johanson, U., Karlsson, M., Tajkhorshid, E., Neutze, R., & Kjellbom, P. (2006) · Nature · doi:10.1038/nature04316 · Cited by 862
Lipid–protein interactions in double-layered two-dimensional AQP0 crystals
Gonen, T., Cheng, Y., Sliz, P., Hiroaki, Y., Fujiyoshi, Y., Harrison, S. C., & Walz, T. (2005) · Nature · doi:10.1038/nature04321 · Cited by 662
More than just water channels: unexpected cellular roles of aquaporins
Verkman, A. S. (2005) · Journal of Cell Science · doi:10.1242/jcs.02519 · Cited by 604
Targeting Aquaporin-4 Subcellular Localization to Treat Central Nervous System Edema
Kitchen, P., Salman, M. M., Halsey, A. M., Clarke-Bland, C., MacDonald, J. A., Ishida, H., Vogel, H. J., Almutiri, S., Logan, A., Kreida, S., et al. (2020) · Cell · doi:10.1016/j.cell.2020.03.037 · Cited by 452
Implications of the Aquaporin-4 Structure on Array Formation and Cell Adhesion
Hiroaki, Y., Tani, K., Kamegawa, A., Gyobu, N., Nishikawa, K., Suzuki, H., Walz, T., Sasaki, S., Mitsuoka, K., Kimura, K., et al. (2006) · Journal of Molecular Biology · doi:10.1016/j.jmb.2005.10.081 · Cited by 386
Metadata
- Authors
- Harries, W. E. C., Akhavan, D., Miercke, L. J. W., Khademi, S., & Stroud, R. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-09-17
- Volume
- 101
- Issue
- 39
- Pages
- 14045-14050
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1999340580
- Cited by
- 270
- References
- 20
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The channel architecture of aquaporin 0 at a 2.2-Å resolution. https://app.cochat.ai/papers/10.1073/pnas.0405274101
- The paper
- Harries, W. E. C., Akhavan, D., Miercke, L. J. W., Khademi, S., & Stroud, R. M. (2004). The channel architecture of aquaporin 0 at a 2.2-Å resolution. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0405274101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.