The DOI matches its Crossref record.
Mammalian electrophysiology on a microfluidic platform
Open accessAbstract
The recent development of automated patch clamp technology has increased the throughput of electrophysiology but at the expense of visual access to the cells being studied. To improve visualization and the control of cell position, we have developed a simple alternative patch clamp technique based on microfluidic junctions between a main chamber and lateral recording capillaries, all fabricated by micromolding of polydimethylsiloxane (PDMS). PDMS substrates eliminate the need for vibration isolation and allow direct cell visualization and manipulation using standard microscopy. Microfluidic integration allows recording capillaries to be arrayed 20 μm apart, for a total chamber volume of <0.5 nl. The geometry of the recording capillaries permits high-quality, stable, whole-cell seals despite the hydrophobicity of the PDMS surface. Using this device, we are able to demonstrate reliable whole-cell recording of mammalian cells on an inexpensive microfluidic platform. Recordings of activation of the voltage-sensitive potassium channel Kv2.1 in mammalian cells compare well with traditional pipette recordings. The results make possible the integration of whole-cell electrophysiology with easily manufactured microfluidic lab-on-a-chip devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Vertical silicon nanowires as a universal platform for delivering biomolecules into living cells
Shalek, A. K., Robinson, J. T., Karp, E. S., Lee, J. S., Ahn, D.-R., Yoon, M.-H., Sutton, A., Jorgolli, M., Gertner, R. S., Gujral, T. S., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909350107 · Cited by 569
Review of cell and particle trapping in microfluidic systems
Nilsson, J., Evander, M., Hammarström, B., & Laurell, T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.017 · Cited by 534
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Metadata
- Authors
- Ionescu-Zanetti, C., Shaw, R. M., Seo, J., Jan, Y.-N., Jan, L. Y., & Lee, L. P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-06-20
- Volume
- 102
- Issue
- 26
- Pages
- 9112-9117
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1991060942
- Cited by
- 178
- References
- 0
- FWCI
- 11.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mammalian electrophysiology on a microfluidic platform. https://app.cochat.ai/papers/10.1073/pnas.0503418102
- The paper
- Ionescu-Zanetti, C., Shaw, R. M., Seo, J., Jan, Y.-N., Jan, L. Y., & Lee, L. P. (2005). Mammalian electrophysiology on a microfluidic platform. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0503418102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.