The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Microoxen: Microorganisms to move microscale loads
Open accessAbstract
It is difficult to harness the power generated by biological motors to carry out mechanical work in systems outside the cell. Efforts to capture the mechanical energy of nanomotors ex vivo require in vitro reconstitution of motor proteins and, often, protein engineering. This study presents a method for harnessing the power produced by biological motors that uses intact cells. The unicellular, biflagellated algae Chlamydomonas reinhardtii serve as “microoxen.” This method uses surface chemistry to attach loads (1- to 6-μm-diameter polystyrene beads) to cells, phototaxis to steer swimming cells, and photochemistry to release loads. These motile microorganisms can transport microscale loads (3-μm-diameter beads) at velocities of ≈100–200 μm·sec –1 and over distances as large as 20 cm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004) · Science · doi:10.1126/science.1093753 · Cited by 965
Direct observation of single kinesin molecules moving along microtubules
Vale, R. D., Funatsu, T., Pierce, D. W., Romberg, L., Harada, Y., & Yanagida, T. (1996) · Nature · doi:10.1038/380451a0 · Cited by 711
Cited by
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Self-citationDi Leonardo, R., Angelani, L., Dell’Arciprete, D., Ruocco, G., Iebba, V., Schippa, S., Conte, M. P., Mecarini, F., De Angelis, F., & Di Fabrizio, E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910426107 · Cited by 707
Programmable artificial phototactic microswimmer
Dai, B., Wang, J., Xiong, Z., Zhan, X., Dai, W., Li, C.-C., Feng, S.-P., & Tang, J. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.187 · Cited by 553
Development of a Sperm‐Flagella Driven Micro‐Bio‐Robot
Magdanz, V., Sanchez, S., & Schmidt, O. G. (2013) · Advanced Materials · doi:10.1002/adma.201302544 · Cited by 444
Catalytic Motors for Transport of Colloidal Cargo
Sundararajan, S., Lammert, P. E., Zudans, A. W., Crespi, V. H., & Sen, A. (2008) · Nano Letters · doi:10.1021/nl072275j · Cited by 388
Metadata
- Authors
- Weibel, D. B., Garstecki, P., Ryan, D., DiLuzio, W. R., Mayer, M., Seto, J. E., & Whitesides, G. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-08-15
- Volume
- 102
- Issue
- 34
- Pages
- 11963-11967
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2073338716
- Cited by
- 410
- References
- 3
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microoxen: Microorganisms to move microscale loads. https://app.cochat.ai/papers/10.1073/pnas.0505481102
- The paper
- Weibel, D. B., Garstecki, P., Ryan, D., DiLuzio, W. R., Mayer, M., Seto, J. E., & Whitesides, G. M. (2005). Microoxen: Microorganisms to move microscale loads. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0505481102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.