The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Activation and repolarization of the normal human heart under complete physiological conditions
Open accessAbstract
Knowledge of normal human cardiac excitation stems from isolated heart or intraoperative mapping studies under nonphysiological conditions. Here, we use a noninvasive imaging modality (electrocardiographic imaging) to study normal activation and repolarization in intact unanesthetized healthy adults under complete physiological conditions. Epicardial potentials, electrograms, and isochrones were noninvasively reconstructed. The normal electrophysiological sequence during activation and repolarization was imaged in seven healthy subjects (four males and three females). Electrocardiographic imaging depicted salient features of normal ventricular activation, including timing and location of the earliest right ventricular (RV) epicardial breakthrough in the anterior paraseptal region, subsequent RV and left ventricular (LV) breakthroughs, apex-to-base activation of posterior LV, and late activation of LV base or RV outflow tract. The repolarization sequence was unaffected by the activation sequence, supporting the hypothesis that in normal hearts, local action potential duration (APD) determines local repolarization time. Mean activation recovery interval (ARI), reflecting local APD, was in the typical human APD range (235 ms). Mean LV apex-to-base ARI dispersion was 42 ms. Average LV ARI exceeded RV ARI by 32 ms. Atrial images showed activation spreading from the sinus node to the rest of the atria, ending at the left atrial appendage. This study provides previously undescribed characterization of human cardiac activation and repolarization under normal physiological conditions. A common sequence of activation was identified, with interindividual differences in specific patterns. The repolarization sequence was determined by local repolarization properties rather than by the activation sequence, and significant dispersion of repolarization was observed between RV and LV and from apex to base.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y. (2004) · Nature Medicine · doi:10.1038/nm1011 · Cited by 646
Self-citation
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
O'Hara, T., Virág, L., Varró, A., & Rudy, Y. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002061 · Cited by 1,196
Self-citationGhosh, S., Rhee, E. K., Avari, J. N., Woodard, P. K., & Rudy, Y. (2008) · Circulation · doi:10.1161/circulationaha.108.781658 · Cited by 89
Self-citationBody surface electrocardiographic mapping for non-invasive identification of arrhythmic sources
Shah, A. J., Hocini, M., Pascale, P., Roten, L., Komatsu, Y., Daly, M., Ramoul, K., Denis, A., Derval, N., Sacher, F., et al. (2013) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2013.2.1.16 · Cited by 37
Self-citation
Metadata
- Authors
- Ramanathan, C., Jia, P., Ghanem, R., Ryu, K., & Rudy, Y.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-04-18
- Volume
- 103
- Issue
- 16
- Pages
- 6309-6314
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2165669217
- Cited by
- 261
- References
- 1
- FWCI
- 13.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.