Gas-phase ions of solute species from charged droplets of solutions
Open accessAbstract
Charged droplets, produced by electrostatic dispersion of solutions of amino acids and peptides are driven by a potential difference a countercurrent to a flow of heated nitrogen bath gas. Evaporation of solvent from those droplets increases surface charge density, resulting in subdivision into smaller charged droplets. Each smaller droplet repeats that sequence until the ultimate result is a dispersion of solvent-free solute ions in the bath gas. Surprisingly, mass spectrometric analyses of the final ion-bath gas mixtures showed that the relative abundances of the desolvated ions were substantially higher when the nitrogen bath gas contained vapor of a polar solvent species than when no such solvent vapor was present. Adding solvent vapor to the background bath gas can certainly not increase, but must decrease, the net rate of solvent evaporation from the charged droplets. Consequently, the observed enhancement of ion formation by the presence of solvent vapor in the bath gas constitutes persuasive evidence that the observed solute ions cannot have been produced by the charged residue mechanism originally suggested by Dole et al. [Dole M, et al . (1968) J Chem Phys 49:2240–2249 and Dole M, Rheude A, Mack LL (1970) J Chem Phys 52:4977–4986]. It is therefore concluded that electrospray ions are most likely produced by the ion evaporation mechanism of Iribarne and Thomson [Iribarne JV, Thomson BA (1975) J Chem Phys 64:2287–2294]. Moreover, and probably as important, this observed signal enhancement constitutes a welcome increase in detection sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Self-citationMass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Cited by
Unraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Analytical strategies for LC–MS-based targeted metabolomics
Lu, W., Bennett, B. D., & Rabinowitz, J. D. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.04.031 · Cited by 481
Advances in mass spectrometry-based clinical biomarker discovery
Crutchfield, C. A., Thomas, S. N., Sokoll, L. J., & Chan, D. W. (2016) · Clinical Proteomics · doi:10.1186/s12014-015-9102-9 · Cited by 292
Advances in mass spectrometry-based metabolomics for investigation of metabolites
Ren, J.-L., Zhang, A.-H., Kong, L., & Wang, X.-J. (2018) · RSC Advances · doi:10.1039/c8ra01574k · Cited by 291
Metadata
- Authors
- Nguyen, S., & Fenn, J. B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-01-23
- Volume
- 104
- Issue
- 4
- Pages
- 1111-1117
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1971124725
- Cited by
- 232
- References
- 2
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gas-phase ions of solute species from charged droplets of solutions. https://app.cochat.ai/papers/10.1073/pnas.0609969104
- The paper
- Nguyen, S., & Fenn, J. B. (2007). Gas-phase ions of solute species from charged droplets of solutions. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0609969104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.