The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimal vein density in artificial and real leaves
Open accessAbstract
The long evolution of vascular plants has resulted in a tremendous variety of natural networks responsible for the evaporatively driven transport of water. Nevertheless, little is known about the physical principles that constrain vascular architecture. Inspired by plant leaves, we used microfluidic devices consisting of simple parallel channel networks in a polymeric material layer, permeable to water, to study the mechanisms of and the limits to evaporation-driven flow. We show that the flow rate through our biomimetic leaves increases linearly with channel density (1/ d ) until the distance between channels ( d ) is comparable with the thickness of the polymer layer (δ), above which the flow rate saturates. A comparison with the plant vascular networks shows that the same optimization criterion can be used to describe the placement of veins in leaves. These scaling relations for evaporatively driven flow through simple networks reveal basic design principles for the engineering of evaporation–permeation-driven devices, and highlight the role of physical constraints on the biological design of leaves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Cited by
Brodribb, T. J., & Feild, T. S. (2010) · Ecology Letters · doi:10.1111/j.1461-0248.2009.01410.x · Cited by 421
Angiosperm leaf vein evolution was physiologically and environmentally transformative
Boyce, C. K., Brodribb, T. J., Feild, T. S., & Zwieniecki, M. A. (2009) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2008.1919 · Cited by 385
Self-citationDevelopmentally based scaling of leaf venation architecture explains global ecological patterns
Sack, L., Scoffoni, C., McKown, A. D., Frole, K., Rawls, M., Havran, J. C., Tran, H., & Tran, T. (2012) · Nature Communications · doi:10.1038/ncomms1835 · Cited by 380
Viewing leaf structure and evolution from a hydraulic perspective
Brodribb, T. J., Feild, T. S., & Sack, L. (2010) · Functional Plant Biology · doi:10.1071/fp10010 · Cited by 312
Xylem hydraulic physiology: The functional backbone of terrestrial plant productivity
Brodribb, T. J. (2009) · Plant Science · doi:10.1016/j.plantsci.2009.06.001 · Cited by 303
Metadata
- Authors
- Noblin, X., Mahadevan, L., Coomaraswamy, I. A., Weitz, D. A., Holbrook, N. M., & Zwieniecki, M. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-07-08
- Volume
- 105
- Issue
- 27
- Pages
- 9140-9144
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2140859319
- Cited by
- 181
- References
- 1
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal vein density in artificial and real leaves. https://app.cochat.ai/papers/10.1073/pnas.0709194105
- The paper
- Noblin, X., Mahadevan, L., Coomaraswamy, I. A., Weitz, D. A., Holbrook, N. M., & Zwieniecki, M. A. (2008). Optimal vein density in artificial and real leaves. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0709194105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.