The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis
Open accessAbstract
We have spectroscopically determined breath ammonia levels in seven patients with end-stage renal disease while they were undergoing hemodialysis at the University of California, Los Angeles, dialysis center. We correlated these measurements against simultaneously taken blood samples that were analyzed for blood urea nitrogen (BUN) and creatinine, which are the accepted standards indicating the level of nitrogenous waste loading in a patient's bloodstream. Initial levels of breath ammonia, i.e., at the beginning of dialysis, are between 1,500 ppb and 2,000 ppb (parts per billion). These levels drop very sharply in the first 15–30 min as the dialysis proceeds. We found the reduction in breath ammonia concentration to be relatively slow from this point on to the end of dialysis treatment, at which point the levels tapered off at 150 to 200 ppb. For each breath ammonia measurement, taken at 15–30 min intervals during the dialysis, we also sampled the patient's blood for BUN and creatinine. The breath ammonia data were available in real time, whereas the BUN and creatinine data were available generally 24 h later from the laboratory. We found a good correlation between breath ammonia concentration and BUN and creatinine. For one of the patients, the correlation gave an R2 of 0.95 for breath ammonia and BUN correlation and an R2 of 0.83 for breath ammonia and creatinine correlation. These preliminary data indicate the possibility of using the real-time breath ammonia measurements for determining efficacy and endpoint of hemodialysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor
Palmer, R. M. J., Ferrige, A. G., & Moncada, S. (1987) · Nature · doi:10.1038/327524a0 · Cited by 10,704
(1978) · Biochemical Education · doi:10.1016/0307-4412(78)90049-3 · Cited by 5,046
THE HITRAN MOLECULAR SPECTROSCOPIC DATABASE AND HAWKS (HITRAN ATMOSPHERIC WORKSTATION): 1996 EDITION
ROTHMAN, L. S., RINSLAND, C. P., GOLDMAN, A., MASSIE, S. T., EDWARDS, D. P., FLAUD, J.-M., PERRIN, A., CAMY-PEYRET, C., DANA, V., MANDIN, J.-Y., et al. (1998) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(98)00078-8 · Cited by 1,925
Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
O’Keefe, A., & Deacon, D. A. G. (1988) · Review of Scientific Instruments · doi:10.1063/1.1139895 · Cited by 1,597
Increased amount of nitric oxide in exhaled air of asthmatics
Alving, K., Weitzberg, E., & Lundberg, J. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06091368 · Cited by 1,232
Variation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738
High nitric oxide production in human paranasal sinuses
Lundberg, J. O. N., Farkas-Szallasi, T., Weitzberg, E., Rinder, J., Lidholm, J., Änggåard, A., Hökfelt, T., Lundberg, J. M., & Alving, K. (1995) · Nature Medicine · doi:10.1038/nm0495-370 · Cited by 628
Fontijn, A., Sabadell, A. J., & Ronco, R. J. (1970) · Analytical Chemistry · doi:10.1021/ac60288a034 · Cited by 463
Vella, F. (1993) · Biochemical Education · doi:10.1016/0307-4412(93)90158-v · Cited by 434
Scherer, J. J., Paul, J. B., O’Keefe, A., & Saykally, R. J. (1997) · Chemical Reviews · doi:10.1021/cr930048d · Cited by 433
Cited by
Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Choi, S.-J., Jang, B.-H., Lee, S.-J., Min, B. K., Rothschild, A., & Kim, I.-D. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am405088q · Cited by 393
Mishra, S. K., Tripathi, S. N., Choudhary, V., & Gupta, B. D. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.03.109 · Cited by 277
Gas identification with graphene plasmons
Hu, H., Yang, X., Guo, X., Khaliji, K., Biswas, S. R., García de Abajo, F. J., Low, T., Sun, Z., & Dai, Q. (2019) · Nature Communications · doi:10.1038/s41467-019-09008-0 · Cited by 225
Metadata
- Authors
- Narasimhan, L. R., Goodman, W., & Patel, C. K. N.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-04-10
- Volume
- 98
- Issue
- 8
- Pages
- 4617-4621
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1968237824
- Cited by
- 379
- References
- 16
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis. https://app.cochat.ai/papers/10.1073/pnas.071057598
- The paper
- Narasimhan, L. R., Goodman, W., & Patel, C. K. N. (2001). Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.071057598
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.