Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

S4-based voltage sensors have three major conformations

Open access
Villalba-Galea, Carlos A., Sandtner, Walter, Starace, Dorine M., Bezanilla, Francisco·2008·Proceedings of the National Academy of Sciences

Abstract

Voltage sensors containing the charged S4 membrane segment display a gating charge vs. voltage ( Q–V ) curve that depends on the initial voltage. The voltage-dependent phosphatase (Ci-VSP), which does not have a conducting pore, shows the same phenomenon and the Q–V recorded with a depolarized initial voltage is more stable by at least 3 RT . The leftward shift of the Q–V curve under prolonged depolarization was studied in the Ci-VSP by using electrophysiological and site-directed fluorescence measurements. The fluorescence shows two components: one that traces the time course of the charge movement between the resting and active states and a slower component that traces the transition between the active state and a more stable state we call the relaxed state. Temperature dependence shows a large negative enthalpic change when going from the active to the relaxed state that is almost compensated by a large negative entropic change. The Q–V curve midpoint measured for pulses that move the sensor between the resting and active states, but not long enough to evolve into the relaxed states, show a periodicity of 120°, indicating a 3 10 secondary structure of the S4 segment when determined under histidine scanning. We hypothesize that the S4 segment moves as a 3 10 helix between the resting and active states and that it converts to an α-helix when evolving into the relaxed state, which is most likely to be the state captured in the crystal structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0807387105

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 208

Metadata

Authors
Villalba-Galea, C. A., Sandtner, W., Starace, D. M., & Bezanilla, F.
Venue
Proceedings of the National Academy of Sciences
Published
2008-11-18
Volume
105
Issue
46
Pages
17600-17607
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2025385677
Cited by
208
References
1
FWCI
7.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: S4-based voltage sensors have three major conformations. https://app.cochat.ai/papers/10.1073/pnas.0807387105
The paper
Villalba-Galea, C. A., Sandtner, W., Starace, D. M., & Bezanilla, F. (2008). S4-based voltage sensors have three major conformations. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0807387105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.