The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Targeting stents with local delivery of paclitaxel-loaded magnetic nanoparticles using uniform fields
Open accessAbstract
The use of stents for vascular disease has resulted in a paradigm shift with significant improvement in therapeutic outcomes. Polymer-coated drug-eluting stents (DES) have also significantly reduced the incidence of reobstruction post stenting, a disorder termed in-stent restenosis. However, the current DESs lack the capacity for adjustment of the drug dose and release kinetics to the disease status of the treated vessel. We hypothesized that these limitations can be addressed by a strategy combining magnetic targeting via a uniform field-induced magnetization effect and a biocompatible magnetic nanoparticle (MNP) formulation designed for efficient entrapment and delivery of paclitaxel (PTX). Magnetic treatment of cultured arterial smooth muscle cells with PTX-loaded MNPs caused significant cell growth inhibition, which was not observed under nonmagnetic conditions. In agreement with the results of mathematical modeling, significantly higher localization rates of locally delivered MNPs to stented arteries were achieved with uniform-field–controlled targeting compared to nonmagnetic controls in the rat carotid stenting model. The arterial tissue levels of stent-targeted MNPs remained 4- to 10-fold higher in magnetically treated animals vs. control over 5 days post delivery. The enhanced retention of MNPs at target sites due to the uniform field-induced magnetization effect resulted in a significant inhibition of in-stent restenosis with a relatively low dose of MNP-encapsulated PTX (7.5 μg PTX/stent). Thus, this study demonstrates the feasibility of site-specific drug delivery to implanted magnetizable stents by uniform field-controlled targeting of MNPs with efficacy for in-stent restenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a follow-up study using the same experimental setup, the group used magnetic nanoparticles loaded with paclitaxel for local delivery, and they observed a substantial reduction in restenosis with low doses of paclitaxel103.”
From Perspectives and opportunities for nanomedicine in the management of atherosclerosis (2011) · cites this paper as [103]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peters, T. (1985) · Advances in protein chemistry · doi:10.1016/s0065-3233(08)60065-0 · Cited by 2,196
Long-Term Outcomes with Drug-Eluting Stents versus Bare-Metal Stents in Sweden
Lagerqvist, B., James, S. K., Stenestrand, U., Lindbäck, J., Nilsson, T., & Wallentin, L. C. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067722 · Cited by 1,197
Colombo, A., Drzewiecki, J., BANNING, A. P., Grube, E., Hauptmann, K. E., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,015
Microencapsulation : methods and industrial applications
Benita, S. (1996) · Medical Entomology and Zoology · Cited by 811
In vivo evaluation of polymeric micellar paclitaxel formulation: toxicity and efficacy
Kim, S. C., Kim, D. W., Shim, Y. H., Bang, J. S., Oh, H. S., Kim, S. W., & Seo, M. H. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00275-9 · Cited by 734
Duda, S. H., Bosiers, M., Lämmer, J., Scheinert, D., Zeller, T., Oliva, V. L., Tielbeek, A. V., Anderson, J., Wiesinger, B., Tepe, G., et al. (2006) · Journal of Endovascular Therapy · doi:10.1583/05-1704.1 · Cited by 488
Preparation of Ultrafine Fe3O4Particles by Precipitation in the Presence of PVA at High pH
Lee, J., Isobe, T., & Senna, M. (1996) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1996.0062 · Cited by 425
Duda, S. H., Bosiers, M., Lämmer, J., Scheinert, D., Zeller, T., Tielbeek, A. V., Anderson, J., Wiesinger, B., Tepe, G., Lansky, A. J., et al. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000151260.74519.ca · Cited by 405
Drug release from microdisperse systems: a critical review
Washington, C. (1990) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(90)90280-h · Cited by 315
Moghimi, S. M., Porter, C. J. H., Muir, I. S., Illum, L., & Davis, S. S. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91869-e · Cited by 283
Cited by
Sorted by citations
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Biological applications of magnetic nanoparticles
Colombo, M., Carregal‐Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,340
Stability of nanofluid: A review
Chakraborty, S., & Panigrahi, P. K. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.115259 · Cited by 735
Magnetic responsive polymer composite materials
Thévenot, J., Oliveira, H., Sandre, O., & Lecommandoux, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60058k · Cited by 638
Multifunctional Nanoparticles for Drug Delivery and Molecular Imaging
Bao, G., Mitragotri, S., & Tong, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152409 · Cited by 549
Metadata
- Authors
- Chorny, M., Fishbein, I., Yellen, B. B., Alferiev, I. S., Bakay, M., Ganta, S., Adamo, R., Amiji, M., Friedman, G., & Levy, R. J.
- Affiliations
- Children's Hospital of Philadelphia (US)
- Duke University (US)
- Northeastern University (US)
- Drexel University (US)
- Corresponding author
- Levy, Robert J.
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2010-04-19
- Volume
- 107
- Issue
- 18
- Pages
- 8346-8351
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC2889533
- OpenAlex
- W2154590970
- Cited by
- 197
- References
- 30
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 9 · 2021: 12 · 2020: 6 · 2019: 10 · 2018: 13 · 2017: 17 · 2016: 18 · 2015: 8 · 2014: 20 · 2013: 16 · 2012: 21
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Heart Association
- Children's Hospital of Philadelphia
- National Institutes of Health
- National Heart, Lung, and Blood Institute (T32HL007915)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Keywords
- drug-eluting stents, paclitaxel, magnetic nanoparticles, magnetic targeting, uniform magnetic field, in-stent restenosis, local drug delivery, arterial smooth muscle cells, carotid artery stenting, nanoparticle retention, vascular disease
- MeSH terms
- Animals, Cell Line, Graft Occlusion, Vascular, Magnetics, Male, Stents, Drug Delivery Systems, Rats, Sprague-Dawley, Paclitaxel, Microscopy, Electron, Transmission, Cell Proliferation, Rats, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review