The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Predicting human blood viscosity in silico
Open accessAbstract
The viscosity of blood has long been used as an indicator in the understanding and treatment of disease, and the advent of modern viscometers allows its measurement with ever-improving clinical convenience. However, these advances have not been matched by theoretical developments that can yield a quantitative understanding of blood’s microrheology and its possible connection to relevant biomolecules (e.g., fibrinogen). Using coarse-grained molecular dynamics and two different red blood cell models, we accurately predict the dependence of blood viscosity on shear rate and hematocrit. We explicitly represent cell–cell interactions and identify the types and sizes of reversible rouleaux structures that yield a tremendous increase of blood viscosity at low shear rates. We also present the first quantitative estimates of the magnitude of adhesive forces between red cells. In addition, our simulations support the hypothesis, previously deduced from experiments, of yield stress as an indicator of cell aggregation. This non-Newtonian behavior is analyzed and related to the suspension’s microstructure, deformation, and dynamics of single red blood cells. The most complex cell dynamics occurs in the intermediate shear rate regime, where individual cells experience severe deformation and transient folded conformations. The generality of these cell models together with single-cell measurements points to the future prediction of blood-viscosity anomalies and the corresponding microstructures associated with various diseases (e.g., malaria, AIDS, and diabetes mellitus). The models can easily be adapted to tune the properties of a much wider class of complex fluids including capsule and vesicle suspensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulating microscopic hydrodynamic phenomena with dissipative particle dynamics
Hoogerbrugge, P. J., & Koelman, J. M. V. A. (1992) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/19/3/001 · Cited by 3,811
Statistical Mechanics of Dissipative Particle Dynamics
Español, P., & Warren, P. (1995) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/30/4/001 · Cited by 2,835
Cell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
Suresh, S., Spatz, J., Mills, J. P., Micoulet, A., Dao, M., Lim, C. T., Beil, M., & Seufferlein, T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.001 · Cited by 878
A Multiscale Red Blood Cell Model with Accurate Mechanics, Rheology, and Dynamics
Fedosov, D. A., Caswell, B., & Karniadakis, G. E. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.02.002 · Cited by 618
Self-citationShape transitions of fluid vesicles and red blood cells in capillary flows
Noguchi, H., & Gompper, G. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504243102 · Cited by 580
Self-citationEffects of hematocrit and plasma proteins on human blood rheology at low shear rates.
Chien, S., Usami, S., Taylor, H. M., Lundberg, J. L., & Gregersen, M. I. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.81 · Cited by 507
Accurate Coarse-Grained Modeling of Red Blood Cells
Pivkin, I. V., & Karniadakis, G. E. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.118105 · Cited by 391
Self-citationSwinging of Red Blood Cells under Shear Flow
Abkarian, M., Faivre, M., & Viallat, A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.188302 · Cited by 341
Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries
McWhirter, J. L., Noguchi, H., & Gompper, G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811484106 · Cited by 300
Self-citation
Cited by
Computer Simulation of Liquids
Allen, M. P., & Tildesley, D. J. (2017) · doi:10.1093/oso/9780198803195.001.0001 · Cited by 20,945
Li, Y., Yuan, H., von dem Bussche, A., Creighton, M., Hurt, R. H., Kane, A. B., & Gao, H. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222276110 · Cited by 755
Perspective: Dissipative particle dynamics
Español, P., & Warren, P. B. (2017) · The Journal of Chemical Physics · doi:10.1063/1.4979514 · Cited by 578
Margination of micro- and nano-particles in blood flow and its effect on drug delivery
Müller, K., Fedosov, D. A., & Gompper, G. (2014) · Scientific Reports · doi:10.1038/srep04871 · Cited by 312
Self-citationMultiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Self-citation
Metadata
- Authors
- Fedosov, D. A., Pan, W., Caswell, B., Gompper, G., & Karniadakis, G. E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-07-05
- Volume
- 108
- Issue
- 29
- Pages
- 11772-11777
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2084652263
- Cited by
- 371
- References
- 25
- FWCI
- 15.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predicting human blood viscosity in silico. https://app.cochat.ai/papers/10.1073/pnas.1101210108
- The paper
- Fedosov, D. A., Pan, W., Caswell, B., Gompper, G., & Karniadakis, G. E. (2011). Predicting human blood viscosity in silico. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1101210108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.