The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Characterization and adaptive optical correction of aberrations during in vivo imaging in the mouse cortex
Open accessAbstract
The signal and resolution during in vivo imaging of the mouse brain is limited by sample-induced optical aberrations. We find that, although the optical aberrations can vary across the sample and increase in magnitude with depth, they remain stable for hours. As a result, two-photon adaptive optics can recover diffraction-limited performance to depths of 450 μm and improve imaging quality over fields of view of hundreds of microns. Adaptive optical correction yielded fivefold signal enhancement for small neuronal structures and a threefold increase in axial resolution. The corrections allowed us to detect smaller neuronal structures at greater contrast and also improve the signal-to-noise ratio during functional Ca 2+imaging in single neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning-related fine-scale specificity imaged in motor cortex circuits of behaving mice
Komiyama, T., Sato, T. R., O’Connor, D. H., Zhang, Y.-X., Huber, D., Hooks, B. M., Gabitto, M., & Svoboda, K. (2010) · Nature · doi:10.1038/nature08897 · Cited by 447
Self-citation
Cited by
Adaptive optical microscopy: the ongoing quest for a perfect image
Booth, M. J. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.46 · Cited by 645
A large field of view two-photon mesoscope with subcellular resolution for in vivo imaging
Sofroniew, N. J., Flickinger, D., King, J., & Svoboda, K. (2016) · eLife · doi:10.7554/elife.14472 · Cited by 645
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Self-citationImaging Live-Cell Dynamics and Structure at the Single-Molecule Level
Liu, Z., Lavis, L. D., & Betzig, E. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.033 · Cited by 486
Self-citationTargeting neurons and photons for optogenetics
Packer, A. M., Roska, B., & Häusser, M. (2013) · Nature Neuroscience · doi:10.1038/nn.3427 · Cited by 348
Metadata
- Authors
- Ji, N., Sato, T. R., & Betzig, E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-12-21
- Volume
- 109
- Issue
- 1
- Pages
- 22-27
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1971743972
- Cited by
- 192
- References
- 1
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization and adaptive optical correction of aberrations during in vivo imaging in the mouse cortex. https://app.cochat.ai/papers/10.1073/pnas.1109202108
- The paper
- Ji, N., Sato, T. R., & Betzig, E. (2012). Characterization and adaptive optical correction of aberrations during in vivo imaging in the mouse cortex. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1109202108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.