CoChat

Room temperature femtosecond X-ray diffraction of photosystem II microcrystals

Open access
Kern, Jan, Alonso-Mori, Roberto, Hellmich, Julia, Tran, Rosalie, Hattne, Johan, Laksmono, Hartawan, Glöckner, Carina, Echols, Nathaniel, Sierra, Raymond G., Sellberg, Jonas, Lassalle-Kaiser, Benedikt, Gildea, Richard J., Glatzel, Pieter, Grosse-Kunstleve, Ralf W., Latimer, Matthew J., McQueen, Trevor A., DiFiore, Dörte, Fry, Alan R., Messerschmidt, Marc, Miahnahri, Alan, Schafer, Donald W., Seibert, M. Marvin, Sokaras, Dimosthenis, Weng, Tsu-Chien, Zwart, Petrus H., White, William E., Adams, Paul D., Bogan, Michael J., Boutet, Sébastien, Williams, Garth J., Messinger, Johannes, Sauter, Nicholas K., Zouni, Athina, Bergmann, Uwe, Yano, Junko, Yachandra, Vittal K. · 2012 · Proceedings of the National Academy of Sciences
Cited by 169

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Most of the dioxygen on earth is generated by the oxidation of water by photosystem II (PS II) using light from the sun. This light-driven, four-photon reaction is catalyzed by the Mn 4 CaO 5 cluster located at the lumenal side of PS II. Various X-ray studies have been carried out at cryogenic temperatures to understand the intermediate steps involved in the water oxidation mechanism. However, the necessity for collecting data at room temperature, especially for studying the transient steps during the O–O bond formation, requires the development of new methodologies. In this paper we report room temperature X-ray diffraction data of PS II microcrystals obtained using ultrashort (< 50 fs) 9 keV X-ray pulses from a hard X-ray free electron laser, namely the Linac Coherent Light Source. The results presented here demonstrate that the ”probe before destroy” approach using an X-ray free electron laser works even for the highly-sensitive Mn 4 CaO 5 cluster in PS II at room temperature. We show that these data are comparable to those obtained in synchrotron radiation studies as seen by the similarities in the overall structure of the helices, the protein subunits and the location of the various cofactors. This work is, therefore, an important step toward future studies for resolving the structure of the Mn 4 CaO 5 cluster without any damage at room temperature, and of the reaction intermediates of PS II during O–O bond formation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.1204598109

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • First lasing and operation of an ångstrom-wavelength free-electron laser

    Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167 · cited 1×

    “The diffraction intensities varied strongly from shot to shot due to several factors, such as the size of the probed crystal volume, the quality of the microcrystals and orientation, and variations in the intensity of the beam due to the nature of the LCLS X-ray pulses (47).”
    BackgroundSelf-citation
  • Potential for biomolecular imaging with femtosecond X-ray pulses

    Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×

    “The diffraction measurement at these doses, well above the Henderson/Garman limit and at room temperature, is only possible because the short X-ray pulses (<50 fs) outrun the X-ray induced damage and the Coulomb explosion (42, 51).”
    Background

Cited by

See all 169

Metadata

Authors
Kern, J., Alonso-Mori, R., Hellmich, J., Tran, R., Hattne, J., Laksmono, H., Glöckner, C., Echols, N., Sierra, R. G., Sellberg, J., Lassalle-Kaiser, B., Gildea, R. J., Glatzel, P., Grosse-Kunstleve, R. W., Latimer, M. J., McQueen, T. A., DiFiore, D., Fry, A. R., Messerschmidt, M., Miahnahri, A., Schafer, D. W., Seibert, M. M., Sokaras, D., Weng, T.-C., Zwart, P. H., White, W. E., Adams, P. D., Bogan, M. J., Boutet, S., Williams, G. J., Messinger, J., Sauter, N. K., Zouni, A., Bergmann, U., Yano, J., & Yachandra, V. K.
Venue
Proceedings of the National Academy of Sciences
Published
2012-06-04
Volume
109
Issue
25
Pages
9721-9726
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2137207121
Cited by
169
References
2
FWCI
10.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.