CoChat

Roles of cell confluency and fluid shear in 3-dimensional intracellular forces in endothelial cells

Open access
Hur, Sung Sik, del Álamo, Juan C., Park, Joon Seok, Li, Yi-Shuan, Nguyen, Hong A., Teng, Dayu, Wang, Kuei-Chun, Flores, Leona, Alonso-Latorre, Baldomero, Lasheras, Juan C., Chien, Shu · 2012 · Proceedings of the National Academy of Sciences
Cited by 129

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We use a novel 3D inter-/intracellular force microscopy technique based on 3D traction force microscopy to measure the cell–cell junctional and intracellular tensions in subconfluent and confluent vascular endothelial cell (EC) monolayers under static and shear flow conditions. We found that z-direction cell–cell junctional tensions are higher in confluent EC monolayers than those in subconfluent ECs, which cannot be revealed in the previous 2D methods. Under static conditions, subconfluent cells are under spatially non-uniform tensions, whereas cells in confluent monolayers are under uniform tensions. The shear modulations of EC cytoskeletal remodeling, extracellular matrix (ECM) adhesions, and cell–cell junctions lead to significant changes in intracellular tensions. When a confluent monolayer is subjected to flow shear stresses with a high forward component comparable to that seen in the straight part of the arterial system, the intracellular and junction tensions preferentially increase along the flow direction over time, which may be related to the relocation of adherens junction proteins. The increases in intracellular tensions are shown to be a result of chemo-mechanical responses of the ECs under flow shear rather than a direct result of mechanical loading. In contrast, the intracellular tensions do not show a preferential orientation under oscillatory flow with a very low mean shear. These differences in the directionality and magnitude of intracellular tensions may modulate translation and transcription of ECs under different flow patterns, thus affecting their susceptibility for atherogenesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.1207326109

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 129

Metadata

Authors
Hur, S. S., del Álamo, J. C., Park, J. S., Li, Y.-S., Nguyen, H. A., Teng, D., Wang, K.-C., Flores, L., Alonso-Latorre, B., Lasheras, J. C., & Chien, S.
Venue
Proceedings of the National Academy of Sciences
Published
2012-06-04
Volume
109
Issue
28
Pages
11110-11115
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2011553458
Cited by
129
References
3
FWCI
5.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Roles of cell confluency and fluid shear in 3-dimensional intracellular forces in endothelial cells. https://app.cochat.ai/papers/10.1073/pnas.1207326109
The paper
Hur, S. S., del Álamo, J. C., Park, J. S., Li, Y.-S., Nguyen, H. A., Teng, D., Wang, K.-C., Flores, L., Alonso-Latorre, B., Lasheras, J. C., & Chien, S. (2012). Roles of cell confluency and fluid shear in 3-dimensional intracellular forces in endothelial cells. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1207326109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.