Molecular dynamics of ion transport through the open conformation of a bacterial voltage-gated sodium channel
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The crystal structure of the open conformation of a bacterial voltage-gated sodium channel pore from Magnetococcus sp . (NaVMs) has provided the basis for a molecular dynamics study defining the channel’s full ion translocation pathway and conductance process, selectivity, electrophysiological characteristics, and ion-binding sites. Microsecond molecular dynamics simulations permitted a complete time-course characterization of the protein in a membrane system, capturing the plethora of conductance events and revealing a complex mixture of single and multi-ion phenomena with decoupled rapid bidirectional water transport. The simulations suggest specific localization sites for the sodium ions, which correspond with experimentally determined electron density found in the selectivity filter of the crystal structure. These studies have also allowed us to identify the ion conductance mechanism and its relation to water movement for the NavMs channel pore and to make realistic predictions of its conductance properties. The calculated single-channel conductance and selectivity ratio correspond closely with the electrophysiology measurements of the NavMs channel expressed in HEK 293 cells. The ion translocation process seen in this voltage-gated sodium channel is clearly different from that exhibited by members of the closely related family of voltage-gated potassium channels and also differs considerably from existing proposals for the conductance process in sodium channels. These studies simulate sodium channel conductance based on an experimentally determined structure of a sodium channel pore that has a completely open transmembrane pathway and activation gate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VMD: visual molecular dynamics
Humphrey, W., Dalke, A., & Schulten, K. (1996) · Journal of Molecular Graphics · doi:10.1016/0263-7855(96)00018-5 · Cited by 66,952 · cited 1×
“Structures were displayed using VMD software (38), electron density maps were displayed in COOT (39), and calculations of the accessible area in the pore were done using Pore Walker software (40).”
Comparison of simple potential functions for simulating liquid water
Jorgensen, W. L., Chandrasekhar, J., Madura, J. D., Impey, R. W., & Klein, M. L. (1983) · The Journal of Chemical Physics · doi:10.1063/1.445869 · Cited by 41,298 · cited 1×
“Molecular dynamics simulations were performed using the Anton machine at the Pittsburgh Supercomputing Center with CHARMM27 protein (26) and CHARMM36 lipid force fields (27) and TIP3P water models (28).”
MethodMolecular dynamics with coupling to an external bath
Berendsen, H. J. C., Postma, J. P. M., van Gunsteren, W. F., DiNola, A., & Haak, J. R. (1984) · The Journal of Chemical Physics · doi:10.1063/1.448118 · Cited by 30,700 · cited 1×
“6 × 10 bar and time constant τP = 1 ps (36).”
Coot : model-building tools for molecular graphics
Emsley, P., & Cowtan, K. (2004) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444904019158 · Cited by 30,571 · cited 1×
“Structures were displayed using VMD software (38), electron density maps were displayed in COOT (39), and calculations of the accessible area in the pore were done using Pore Walker software (40).”
LINCS: A linear constraint solver for molecular simulations
Hess, B., Bekker, H., Berendsen, H. J. C., & Fraaije, J. G. E. M. (1997) · Journal of Computational Chemistry · doi:10.1002/(sici)1096-987x(199709)18:12<1463::aid-jcc4>3.0.co;2-h · Cited by 18,260
Canonical sampling through velocity rescaling
Bussi, G., Donadio, D., & Parrinello, M. (2007) · The Journal of Chemical Physics · doi:10.1063/1.2408420 · Cited by 18,089 · cited 1×
“1 ps using weak temperature coupling (35).”
Jorgensen, W. L., Maxwell, D. S., & Tirado-Rives, J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9621760 · Cited by 15,409 · cited 1×
“com) software with the OPLS all-atom protein force field (32) and TIP3P water model.”
All-Atom Empirical Potential for Molecular Modeling and Dynamics Studies of Proteins
MacKerell, A. D., Bashford, D., Bellott, M., Dunbrack, R. L., Evanseck, J. D., Field, M. J., Fischer, S., Gao, J., Guo, H., Ha, S., et al. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp973084f · Cited by 14,311 · cited 1×
“Molecular dynamics simulations were performed using the Anton machine at the Pittsburgh Supercomputing Center with CHARMM27 protein (26) and CHARMM36 lipid force fields (27) and TIP3P water models (28).”
MethodGROMACS: A message-passing parallel molecular dynamics implementation
Berendsen, H. J. C., van der Spoel, D., & van Drunen, R. (1995) · Computer Physics Communications · doi:10.1016/0010-4655(95)00042-e · Cited by 10,405
The Structure of the Potassium Channel: Molecular Basis of K + Conduction and Selectivity
Doyle, D. A., Cabral, J. M., Pfuetzner, R. A., Kuo, A., Gulbis, J. M., Cohen, S. L., Chait, B. T., & MacKinnon, R. (1998) · Science · doi:10.1126/science.280.5360.69 · Cited by 6,807 · cited 1×
“In homotetrameric potassium channels, each of the four monomers contributes to the binding of a dehydrated K through their main chain carbonyls (15).”
Cited by
Voltage-gated sodium channels: structure, function, pharmacology, and clinical indications
de Lera Ruiz, M., & Kraus, R. L. (2015) · Journal of Medicinal Chemistry · doi:10.1021/jm501981g · Cited by 548
Emerging Diversity in Lipid–Protein Interactions
Corradi, V., Sejdiu, B. I., Mesa-Galloso, H., Abdizadeh, H., Noskov, S. Y., Marrink, S. J., & Tieleman, D. P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00451 · Cited by 459
The hitchhiker’s guide to the voltage-gated sodium channel galaxy
Ahern, C. A., Payandeh, J., Bosmans, F., & Chanda, B. (2016) · Journal of General Physiology · doi:10.1085/jgp.201511492 · Cited by 358
Structure and Pharmacology of Voltage-Gated Sodium and Calcium Channels
Catterall, W. A., Lenaeus, M. J., & Gamal El-Din, T. M. (2020) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010818-021757 · Cited by 281
Bioinspired Graphene Nanopores with Voltage-Tunable Ion Selectivity for Na+ and K+
He, Z., Zhou, J., Lu, X., & Corry, B. (2013) · ACS Nano · doi:10.1021/nn4043628 · Cited by 249
Structure and function of voltage‐gated sodium channels at atomic resolution
Catterall, W. A. (2014) · Experimental Physiology · doi:10.1113/expphysiol.2013.071969 · Cited by 207
“A complementary (and contemporaneous) molecular dynamics study of the NaV channel from Magnetococcus sp. (NaVMs) was based on the open-pore structure derived from X-ray crystallographic studies of the isolated pore domain (Ulmschneider et al. 2013).”
Method
Metadata
- Authors
- Ulmschneider, M. B., Bagnéris, C., McCusker, E. C., DeCaen, P. G., Delling, M., Clapham, D. E., Ulmschneider, J. P., & Wallace, B. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2013-03-29
- Volume
- 110
- Issue
- 16
- Pages
- 6364-6369
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2112846165
- Cited by
- 169
- References
- 38
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.