The DOI matches its Crossref record.
Palette of fluorinated voltage-sensitive hemicyanine dyes
Open accessAbstract
Optical recording of membrane potential permits spatially resolved measurement of electrical activity in subcellular regions of single cells, which would be inaccessible to electrodes, and imaging of spatiotemporal patterns of action potential propagation in excitable tissues, such as the brain or heart. However, the available voltage-sensitive dyes (VSDs) are not always spectrally compatible with newly available optical technologies for sensing or manipulating the physiological state of a system. Here, we describe a series of 19 fluorinated VSDs based on the hemicyanine class of chromophores. Strategic placement of the fluorine atoms on the chromophores can result in either blue or red shifts in the absorbance and emission spectra. The range of one-photon excitation wavelengths afforded by these new VSDs spans 440–670 nm; the two-photon excitation range is 900–1,340 nm. The emission of each VSD is shifted by at least 100 nm to the red of its one-photon excitation spectrum. The set of VSDs, thus, affords an extended toolkit for optical recording to match a broad range of experimental requirements. We show the sensitivity to voltage and the photostability of the new VSDs in a series of experimental preparations ranging in scale from single dendritic spines to whole heart. Among the advances shown in these applications are simultaneous recording of voltage and calcium in single dendritic spines and optical electrophysiology recordings using two-photon excitation above 1,100 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
All-optical electrophysiology in mammalian neurons using engineered microbial rhodopsins
Hochbaum, D. R., Zhao, Y., Farhi, S. L., Klapoetke, N., Werley, C. A., Kapoor, V., Zou, P., Kralj, J. M., Maclaurin, D., Smedemark-Margulies, N., et al. (2014) · Nature Methods · doi:10.1038/nmeth.3000 · Cited by 770
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Photobleaching of organic fluorophores: quantitative characterization, mechanisms, protection *
Demchenko, A. P. (2020) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ab7365 · Cited by 370
Molecular Fluorophores for Deep-Tissue Bioimaging
Wang, S., Li, B., & Zhang, F. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00544 · Cited by 270
Heylman, C., Sobrino, A., Shirure, V. S., Hughes, C. C., & George, S. C. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214525295 · Cited by 53
Metadata
- Authors
- Yan, P., Acker, C. D., Zhou, W.-L., Lee, P., Bollensdorff, C., Negrean, A., Lotti, J., Sacconi, L., Antic, S. D., Kohl, P., Mansvelder, H. D., Pavone, F. S., & Loew, L. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-11-20
- Volume
- 109
- Issue
- 50
- Pages
- 20443-20448
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2108406026
- Cited by
- 170
- References
- 0
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Palette of fluorinated voltage-sensitive hemicyanine dyes. https://app.cochat.ai/papers/10.1073/pnas.1214850109
- The paper
- Yan, P., Acker, C. D., Zhou, W.-L., Lee, P., Bollensdorff, C., Negrean, A., Lotti, J., Sacconi, L., Antic, S. D., Kohl, P., Mansvelder, H. D., Pavone, F. S., & Loew, L. M. (2012). Palette of fluorinated voltage-sensitive hemicyanine dyes. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1214850109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.