Expanded palette of Nano-lanterns for real-time multicolor luminescence imaging
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Significance: The application of luminescence imaging has been limited mainly by the two drawbacks of luciferases: low brightness and poor color variants. Here, we report the development of cyan and orange luminescent proteins approximately 20 times brighter than the wild-type Renilla luciferase. The color change and enhancement of brightness were both achieved by exploring bioluminescence resonance energy transfer (BRET) from enhanced Renilla luciferase to a fluorescent protein, a technology that we previously reported for the development of the bright yellowish-green luminescent protein Nano-lantern. These cyan and orange Nano-lanterns along with the original yellow Nano-lantern enable monitoring of multiple cellular events, including dynamics of subcellular structures, gene expressions, and functional status, such as intracellular Ca 2+ change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dragulescu-Andrasi, A., Chan, C. T., De, A., Massoud, T. F., & Gambhir, S. S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100923108 · Cited by 186 · cited 1×
“Nonetheless, these red variants will have a potential benefit for deep-tissue imaging, because absorption by tissues, especially hemoglobin, is reduced at wavelengths longer than 600 nm (12, 13).”
Background
Cited by
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
All-Optical Interrogation of Neural Circuits
Emiliani, V., Cohen, A. E., Deisseroth, K., & Häusser, M. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.2916-15.2015 · Cited by 354
Namkung, Y., Le Gouill, C., Lukashova, V., Kobayashi, H., Hogue, M., Khoury, E., Song, M., Bouvier, M., & Laporte, S. A. (2016) · Nature Communications · doi:10.1038/ncomms12178 · Cited by 347
Applications of bioluminescence in biotechnology and beyond
Syed, A. J., & Anderson, J. C. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01492c · Cited by 341
In Vivo Molecular Bioluminescence Imaging: New Tools and Applications
Mezzanotte, L., van ‘t Root, M., Karatas, H., Goun, E. A., & Löwik, C. W. G. M. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.012 · Cited by 288
Metadata
- Authors
- Takai, A., Nakano, M., Saito, K., Haruno, R., Watanabe, T. M., Ohyanagi, T., Jin, T., Okada, Y., & Nagai, T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2015-03-23
- Volume
- 112
- Issue
- 14
- Pages
- 4352-4356
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2061338238
- Cited by
- 134
- References
- 1
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expanded palette of Nano-lanterns for real-time multicolor luminescence imaging. https://app.cochat.ai/papers/10.1073/pnas.1418468112
- The paper
- Takai, A., Nakano, M., Saito, K., Haruno, R., Watanabe, T. M., Ohyanagi, T., Jin, T., Okada, Y., & Nagai, T. (2015). Expanded palette of Nano-lanterns for real-time multicolor luminescence imaging. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1418468112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.