The DOI matches its Crossref record.
A microscopic view of ion conduction through the K+ channel
Open accessAbstract
Recent results from x-ray crystallography and molecular dynamics free-energy simulations have revealed the existence of a number of specific cation-binding sites disposed along the narrow pore of the K + channel from Streptomyces lividans (KcsA), suggesting that K + ions might literally “hop” in single file from one binding site to the next as permeation proceeds. In support of this view, it was found that the ion configurations correspond to energy wells of similar depth and that ion translocation is opposed only by small energy barriers. Although such features of the multiion potential energy surface are certainly essential for achieving a high throughput rate, diffusional and dissipative dynamical factors must also be taken into consideration to understand how rapid conduction of K + is possible. To elucidate the mechanism of ion conduction, we established a framework theory enabling the direct simulation of nonequilibrium fluxes by extending the results of molecular dynamics over macroscopically long times. In good accord with experimental measurements, the simulated maximum conductance of the channel at saturating concentration is on the order of 550 and 360 pS for outward and inward ions flux, respectively, with a unidirectional flux-ratio exponent of 3. Analysis of the ion-conduction process reveals a lack of equivalence between the cation-binding sites in the selectivity filter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noskov, S. Y., Bernèche, S., & Roux, B. (2004) · Nature · doi:10.1038/nature02943 · Cited by 596
Self-citationTheoretical and computational models of biological ion channels
Roux, B., Allen, T., Bernèche, S., & Im, W. (2004) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583504003968 · Cited by 413
Self-citationEnergetics of ion conduction through the gramicidin channel
Allen, T. W., Andersen, O. S., & Roux, B. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2635314100 · Cited by 369
Self-citationPrinciples of conduction and hydrophobic gating in K + channels
Jensen, M. Ø., Borhani, D. W., Lindorff-Larsen, K., Maragakis, P., Jogini, V., Eastwood, M. P., Dror, R. O., & Shaw, D. E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911691107 · Cited by 311
A gate in the selectivity filter of potassium channels
Bernèche, S., & Roux, B. (2005) · Structure · doi:10.1016/j.str.2004.12.019 · Cited by 214
Metadata
- Authors
- Bernèche, S., & Roux, B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-07
- Volume
- 100
- Issue
- 15
- Pages
- 8644-8648
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2167460012
- Cited by
- 236
- References
- 0
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microscopic view of ion conduction through the K+ channel. https://app.cochat.ai/papers/10.1073/pnas.1431750100
- The paper
- Bernèche, S., & Roux, B. (2003). A microscopic view of ion conduction through the K+ channel. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1431750100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.