A rapid and label-free platform for virus capture and identification from clinical samples
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Emerging and reemerging viruses are responsible for a number of recent epidemic outbreaks. A crucial step in predicting and controlling outbreaks is the timely and accurate characterization of emerging virus strains. We present a portable microfluidic platform containing carbon nanotube arrays with differential filtration porosity for the rapid enrichment and optical identification of viruses. Different emerging strains (or unknown viruses) can be enriched and identified in real time through a multivirus capture component in conjunction with surface-enhanced Raman spectroscopy. More importantly, after viral capture and detection on a chip, viruses remain viable and get purified in a microdevice that permits subsequent in-depth characterizations by various conventional methods. We validated this platform using different subtypes of avian influenza A viruses and human samples with respiratory infections. This technology successfully enriched rhinovirus, influenza virus, and parainfluenza viruses, and maintained the stoichiometric viral proportions when the samples contained more than one type of virus, thus emulating coinfection. Viral capture and detection took only a few minutes with a 70-fold enrichment enhancement; detection could be achieved with as little as 10 2 EID 50 /mL (50% egg infective dose per microliter), with a virus specificity of 90%. After enrichment using the device, we demonstrated by sequencing that the abundance of viral-specific reads significantly increased from 4.1 to 31.8% for parainfluenza and from 0.08 to 0.44% for influenza virus. This enrichment method coupled to Raman virus identification constitutes an innovative system that could be used to quickly track and monitor viral outbreaks in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trimmomatic: a flexible trimmer for Illumina sequence data
Bolger, A. M., Lohse, M., & Usadel, B. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu170 · Cited by 65,548
Analyzing real-time PCR data by the comparative CT method
Schmittgen, T. D., & Livak, K. J. (2008) · Nature Protocols · doi:10.1038/nprot.2008.73 · Cited by 26,190
Ensemble methods in machine learning
Dietterich, T. G. (2000) · Lecture Notes in Computer Science · doi:10.1007/3-540-45014-9_1 · Cited by 8,408
Friedman, J., Hastie, T., & Tibshirani, R. (2000) · The Annals of Statistics · doi:10.1214/aos/1016218223 · Cited by 6,884
metaSPAdes: a new versatile metagenomic assembler
Nurk, S., Meleshko, D., Korobeynikov, A., & Pevzner, P. A. (2017) · Genome Research · doi:10.1101/gr.213959.116 · Cited by 4,496
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 2×
“Under these flow conditions, the fluidic microvortices induced by the herringbonestructured CNxCNT arrays, enhanced the interactions between the silica particles and the CNxCNT arrays during transport through a microfluidic channel (30).”
Logistic regression and Artificial Neural Network Classification models: A methodology review
Dreiseitl, S., & Ohno-Machado, L. (2002) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00034-0 · Cited by 2,177
Quick, J., Grubaugh, N. D., Pullan, S. T., Claro, I. M., Smith, A. D., Gangavarapu, K., Oliveira, G., Robles-Sikisaka, R., Rogers, T. F., Beutler, N. A., et al. (2017) · Nature Protocols · doi:10.1038/nprot.2017.066 · Cited by 1,190
Simner, P. J., Miller, S., & Carroll, K. C. (2018) · Clinical Infectious Diseases · doi:10.1093/cid/cix881 · Cited by 821
Towards a genomics-informed, real-time, global pathogen surveillance system
Gardy, J. L., & Loman, N. J. (2018) · Nature Reviews Genetics · doi:10.1038/nrg.2017.88 · Cited by 771 · cited 11×
“We further analyzed the captured viruses by NGS to characterize the captured virus population without prior knowledge of the strains (14, 20 – 22 , 46).”
InfluentialThe challenge of diagnostic metagenomics
Greninger, A. L. (2018) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2018.1487292 · Cited by 156
Cited by
Ralbovsky, N. M., & Lednev, I. K. (2020) · Chemical Society Reviews · doi:10.1039/d0cs01019g · Cited by 328
Metadata
- Authors
- Yeh, Y.-T., Gulino, K., Zhang, Y., Sabestien, A., Chou, T.-W., Zhou, B., Lin, Z., Albert, I., Lu, H., Swaminathan, V., Ghedin, E., & Terrones, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2019-12-27
- Volume
- 117
- Issue
- 2
- Pages
- 895-901
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2997926335
- Cited by
- 209
- References
- 11
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.