Coherent infrared emission from myoglobin crystals: An electric field measurement
Open accessThe DOI matches its Crossref record.
Abstract
We introduce coherent infrared emission interferometry as a χ (2) vibrational spectroscopy technique and apply it to studying the initial dynamics upon photoactivation of myoglobin (Mb). By impulsive excitation (using 11-fs pulses) of a Mb crystal, vibrations that couple to the optical excitation are set in motion coherently. Because of the order in the crystal lattice the coherent oscillations of the different proteins in the crystal that are associated with charge motions give rise to a macroscopic burst of directional multi-teraHertz radiation. This radiation can be detected in a phase-sensitive way by heterodyning with a broad-band reference field. In this way both amplitude and phase of the different vibrations can be obtained. We detected radiation in the 1,000–1,500 cm −1 frequency region, which contains modes sensitive to the structure of the heme macrocycle, as well as peripheral protein modes. Both in carbonmonoxy-Mb and aquomet-Mb we observed emission from six modes, which were assigned to heme vibrations. The phase factors of the modes contributing to the protein electric field show a remarkable consistency, taking on values that indicate that the dipoles are created “emitting” at t = 0, as one would expect for impulsively activated modes. The few deviations from this behavior in Mb-CO we propose are the result of these modes being sensitive to the photodissociation process and severely disrupted by it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Two-Dimensional Femtosecond Spectroscopy
Jonas, D. M. (2003) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.54.011002.103907 · Cited by 1,198
Exploring Dynamics in the Far-Infrared with Terahertz Spectroscopy
Schmuttenmaer, C. A. (2004) · Chemical Reviews · doi:10.1021/cr020685g · Cited by 659
Electromagnetic cellular interactions
Cifra, M., Fields, J. Z., & Farhadi, A. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.07.003 · Cited by 339
Generation of ultrafast terahertz radiation pulses on metallic nanostructured surfaces
Welsh, G. H., & Wynne, K. (2009) · Optics Express · doi:10.1364/oe.17.002470 · Cited by 88
McKemmish, L. K., Reimers, J. R., McKenzie, R. H., Mark, A. E., & Hush, N. S. (2009) · Physical Review E · doi:10.1103/physreve.80.021912 · Cited by 87
Metadata
- Authors
- Groot, M.-L., Vos, M. H., Schlichting, I., van Mourik, F., Joffre, M., Lambry, J.-C., & Martin, J.-L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-01-29
- Volume
- 99
- Issue
- 3
- Pages
- 1323-1328
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2051266935
- Cited by
- 37
- References
- 0
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coherent infrared emission from myoglobin crystals: An electric field measurement. https://app.cochat.ai/papers/10.1073/pnas.251662698
- The paper
- Groot, M.-L., Vos, M. H., Schlichting, I., van Mourik, F., Joffre, M., Lambry, J.-C., & Martin, J.-L. (2002). Coherent infrared emission from myoglobin crystals: An electric field measurement. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.251662698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.