Use of monoclonal antibodies as sensitive and specific probes for biologically active human gamma-interferon.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Mouse monoclonal antibodies B1 and B3 are specific for natural and Escherichia coli-derived recombinant human gamma-interferon (IFN-gamma). The two antibodies recognize different epitopes of the IFN-gamma molecule and do not compete with each other's binding. We have used these two antibodies to construct a solid-phase, sandwich immunoradiometric assay for human IFN-gamma. Purified antibody B1 was coated on polystyrene beads (0.64 cm in diameter) and used as the solid-phase immunoadsorbent and antibody B3 was labeled with 125I and used as tracer. This assay can be completed in about 4 hr and is capable of detecting IFN-gamma levels in human serum or tissue culture fluids as low as 0.1 NIH reference unit/ml. Recombinant human IFN-gamma derived from E. coli was detectable at a concentration of 0.02 ng/ml. The assay appears to be specific for the biologically active forms of IFN-gamma, since after exposure to pH 2, 37 degrees C, or 56 degrees C, biological activity and reactivity in the immunoradiometric assay decreased in parallel. The immunoradiometric assay can be employed for the analysis of the structural characteristics of the human IFN-gamma molecule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nathan, C. F., Murray, H. W., Wiebe, M. E., & Rubin, B. Y. (1983) · The Journal of experimental medicine · doi:10.1084/jem.158.3.670 · Cited by 1,962
Cited by
Detection of circulating tumor necrosis factor after endotoxin administration
Michie, H. R., Manogue, K. R., Spriggs, D. R., Revhaug, A., O'Dwyer, S., Dinarello, C. A., Cerami, A., Wolff, S. M., & Wilmore, D. W. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806093182301 · Cited by 1,677
The Molecular Cell Biology of Interferon-gamma and its Receptor
Farrar, M. A., & Schreiber, R. D. (1993) · Annual Review of Immunology · doi:10.1146/annurev.iy.11.040193.003035 · Cited by 1,341
The roles of IFNγ in protection against tumor development and cancer immunoediting
Ikeda, H., Old, L. J., & Schreiber, R. D. (2002) · Cytokine & Growth Factor Reviews · doi:10.1016/s1359-6101(01)00038-7 · Cited by 899
Czerkinsky, C., Andersson, G., Ekre, H.-P., Nilsson, L.-Å., Klareskog, L., & Ouchterlony, Ö. (1988) · Journal of Immunological Methods · doi:10.1016/0022-1759(88)90079-8 · Cited by 495
Assessment of Cytokines by Immunofluorescence and the Paraformaldehyde‐Saponin Procedure
Sander, B., Andersson, J., & Andersson, U. (1991) · Immunological Reviews · doi:10.1111/j.1600-065x.1991.tb00578.x · Cited by 452
Metadata
- Authors
- Chang, T. W., McKinney, S., Liu, V, Kung, P. C., Vilcek, J., & Le, J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1984-08
- Volume
- 81
- Issue
- 16
- Pages
- 5219-5222
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2062046966
- Cited by
- 129
- References
- 1
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.