The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Rapid, sensitive analysis of protein mixtures by mass spectrometry.
Open accessAbstract
We have developed a method for determining the molecular masses of proteins in complex mixtures by mass spectrometry. The method has the capacity to examine the components of mixtures without using any chromatographic separation steps and will tolerate relatively large amounts of buffers and inorganic contaminants. It allows the simultaneous determination of protein molecular masses from 1 to 40 kDa with an accuracy of +/- 0.01% and above 40 kDa with reduced accuracy. The lower limit for practical detection of a protein is a concentration of approximately 0.1 microM, and less than 1 microliter of such a solution is consumed. The analysis is very fast: less than 15 min is necessary to perform the complete analysis, including sample preparation, introduction into the mass spectrometer, mass spectrum collection, and data reduction. The mass spectrum that is obtained does not require elaborate interpretation because there is no fragmentation of the ionized protein (or protein subunit) molecule. Therefore, there is a one-to-one correspondence between the peaks in the mass spectrum and the proteins present in the original mixture. The spectra assume the appearance of chromatograms, with the abscissa being mass-to-charge ratio rather than chromatographic retention time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Self-citation[1] Introduction to the plasma lipoproteins
Gotto, A. M., Pownall, H. J., & Havel, R. J. (1986) · Methods in Enzymology · doi:10.1016/0076-6879(86)28061-1 · Cited by 421
Cited by
Weight-Reducing Effects of the Plasma Protein Encoded by the obese Gene
Halaas, J. L., Gajiwala, K. S., Maffei, M., Cohen, S. L., Chait, B. T., Rabinowitz, D., Lallone, R. L., Burley, S. K., & Friedman, J. M. (1995) · Science · doi:10.1126/science.7624777 · Cited by 4,451
Self-citationDoucette, A. A., Vieira, D. B., Orton, D. J., & Wall, M. J. (2014) · Journal of Proteome Research · doi:10.1021/pr500864a · Cited by 63
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Status of, and developments in, mass spectrometry of peptides and proteins
Roepstorff, P., & Richter, W. J. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85085-e · Cited by 15
Metadata
- Authors
- Beavis, R. C., & Chait, B. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1990-09
- Volume
- 87
- Issue
- 17
- Pages
- 6873-6877
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1974302575
- Cited by
- 301
- References
- 3
- FWCI
- 16.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.