High-resolution tandem mass spectrometry of large biomolecules.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Unit-resolution mass spectra have been obtained for peptides as large as 17 kDa, providing information on impurities and adduct ions, as well as accurate molecular weight values. Electrospray ionization produces many multiply-charged species of the same mass; isotopic peak resolution provides direct charge state assignment from the unit mass spacing of the isotopes. This is of special value when the spectrum also has many masses, such as from precursor ion dissociation or impurities. Mass measuring errors not only are concomitantly lower (less than 0.1 Da) than when the isotopic peaks are unresolved but also are independent of variations in 13C/12C natural isotopic abundances. Also, larger errors are avoided that occur when the measured peak envelope includes impurity or adduct ions. This also benefits tandem mass spectrometry; dissociation of peptide ions as large as 8.5 kDa yields fragment masses consistent (less than 0.1 Da) with their amino acid sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Use of mass spectrometric molecular weight information to identify proteins in sequence databases
Mann, M., Højrup, P., & Roepstorff, P. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220605 · Cited by 931
Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Self-citationBanerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“The same instrument was also utilized to perform collision-induced dissociation (CID) and nozzle-skimmer dissociation (NSD) of ubiquitin, using the high resolving power of the instrument to determine charge state and identity of the fragment ions [83].”
MethodCoexisting stable conformations of gaseous protein ions.
Suckau, D., Shi, Y., Beu, S. C., Senko, M. W., Quinn, J. P., Wampler, F. M., & McLafferty, F. W. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.3.790 · Cited by 345
Self-citation
Metadata
- Authors
- Loo, J. A., Quinn, J. P., Ryu, S. I., Henry, K. D., Senko, M. W., & McLafferty, F. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1992-01
- Volume
- 89
- Issue
- 1
- Pages
- 286-289
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2025736749
- Cited by
- 118
- References
- 1
- FWCI
- 11.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution tandem mass spectrometry of large biomolecules. https://app.cochat.ai/papers/10.1073/pnas.89.1.286
- The paper
- Loo, J. A., Quinn, J. P., Ryu, S. I., Henry, K. D., Senko, M. W., & McLafferty, F. W. (1992). High-resolution tandem mass spectrometry of large biomolecules. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.89.1.286
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.