The DOI matches its Crossref record.
Atomic force microscopy of long DNA: imaging in air and under water.
Open accessAbstract
We have obtained striking atomic force microscopy images of the intact lambda bacteriophage genome and of several lambda restriction fragments both in air and under water. The DNA is unstained and the images are stable under continuous scanning for up to 30 min. Measured contour lengths of fully imaged restriction fragments and intact lambda DNA are accurate to within a few percent. The key to this development is the use of a process for binding unmodified double-stranded DNA to chemically treated mica surfaces. This procedure leads to strong DNA attachment and yields high-quality images that are stable under repeated scanning, even with the sample submerged in water. This allows normal hydration conditions to be maintained during scanning and in addition leads to a general improvement of image quality. Both the lateral resolution and the contrast increase by a factor of approximately 3 under water.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“AFM has been indicated as a proper tool for micelles size determination due to its ability to distinguish particles with different dimensions in a mixture as well as to operate at room temperature, thus allowing the analysis of biological samples close to native and physiological conditions [133,[154][155][156].”
From Polymeric micelles in drug delivery: An insight of the techniques for their characterization and assessment in biorelevant conditions (2021) · cites this paper as [154]
Citations
Cited by
Sorted by citations
Ghezzi, M., Pescina, S., Padula, C., Santi, P., Del Favero, E., Cantù, L., & Nicoli, S. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.02.031 · Cited by 1,135
Preparation of DNA and nucleoprotein samples for AFM imaging
Lyubchenko, Y. L. (2011) · Micron · doi:10.1016/j.micron.2010.08.011 · Cited by 93
Self-citation
Metadata
- Authors
- Lyubchenko, Y., Shlyakhtenko, L., Harrington, R., Oden, P., & Lindsay, S.
- Affiliations
- University of Nevada, Reno (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 1993-03-15
- Volume
- 90
- Issue
- 6
- Pages
- 2137-2140
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC46040
- OpenAlex
- W2170678696
- Cited by
- 243
- References
- 0
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 1 · 2019: 8 · 2018: 2 · 2017: 6 · 2016: 8 · 2015: 4 · 2014: 12 · 2013: 10 · 2012: 10
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › DNA and Nucleic Acid Chemistry
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- DNA imaging, restriction fragments, DNA contour length, DNA hydration, image stability, lateral resolution, image contrast
- MeSH terms
- DNA, Viral, Microscopy, Oligodeoxyribonucleotides, Bacteriophage lambda, Genome, Viral
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atomic force microscopy of long DNA: imaging in air and under water. https://app.cochat.ai/papers/10.1073/pnas.90.6.2137
- The paper
- Lyubchenko, Y., Shlyakhtenko, L., Harrington, R., Oden, P., & Lindsay, S. (1993). Atomic force microscopy of long DNA: imaging in air and under water. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.90.6.2137