A mathematical model of the cytosolic-free calcium response in endothelial cells to fluid shear stress
Open accessThe DOI matches its Crossref record.
Abstract
Important among the responses of endothelial cells to flow stimuli are cytosolic-free calcium transients. These transients are mediated by several factors, including blood-borne agonists, extracellular calcium, and fluid-imposed shear forces. A mathematical model has been developed describing the recognition and transduction of shear stress to the second messenger cytosolic calcium. Shear stress modulates the calcium response via at least two modalities. First, mass transfer of agonist to the cell surface is enhanced by perfusion and is thus related to shear stress. Second, the permeability of the cell membrane to extracellular calcium increases upon exposure to shear stress. A mass balance for agonist in the perfusate is coupled to a previously published calcium dynamics model. Computations indicate a flow region where the transient moves from transport limited to kinetically limited. Parametric studies indicate distinct contributions to the time course by each step in the process. These steps include the time to develop the concentration boundary layer of agonist, receptor activation, and the mobilization of calcium from intracellular stores. Exogenous calcium is presumed to enter the cell via shear stress-gated ion channels. The model predicts a sigmoidal dependence of calcium influx upon shear stress. The peak value of the transient is determined largely by the agonist pathway, whereas the plateau level is governed by calcium influx. The model predicts the modulation of the calcium transient in the physiologically relevant range of flow and the associated shear stress. This implies that hemodynamics is important in regulating endothelial biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Shear stress and the endothelium
Ballermann, B. J., Dardik, A., Eng, E., & Liu, A. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.06720.x · Cited by 439
Endothelial permeability, LDL deposition, and cardiovascular risk factors—a review
Mundi, S., Massaro, M., Scoditti, E., Carluccio, M. A., van Hinsbergh, V. W. M., Iruela-Arispe, M. L., & De Caterina, R. (2018) · Cardiovascular Research · doi:10.1093/cvr/cvx226 · Cited by 367
Mukhopadhyay, S., Saha, R., Palanisamy, A., Ghosh, M., Biswas, A., Roy, S., Pal, A., Sarkar, K., & Bagh, S. (2016) · Scientific Reports · doi:10.1038/srep25975 · Cited by 30
Metadata
- Authors
- Wiesner, T. F., Berk, B. C., & Nerem, R. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1997-04-15
- Volume
- 94
- Issue
- 8
- Pages
- 3726-3731
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1985410337
- Cited by
- 73
- References
- 0
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A mathematical model of the cytosolic-free calcium response in endothelial cells to fluid shear stress. https://app.cochat.ai/papers/10.1073/pnas.94.8.3726
- The paper
- Wiesner, T. F., Berk, B. C., & Nerem, R. M. (1997). A mathematical model of the cytosolic-free calcium response in endothelial cells to fluid shear stress. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.94.8.3726
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.