The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Circular permutation and receptor insertion within green fluorescent proteins
Open accessAbstract
Many areas of biology and biotechnology have been revolutionized by the ability to label proteins genetically by fusion to the Aequorea green fluorescent protein (GFP). In previous fusions, the GFP has been treated as an indivisible entity, usually appended to the amino or carboxyl terminus of the host protein, occasionally inserted within the host sequence. The tightly interwoven, three-dimensional structure and intricate posttranslational self-modification required for chromophore formation would suggest that major rearrangements or insertions within GFP would prevent fluorescence. However, we now show that several rearrangements of GFPs, in which the amino and carboxyl portions are interchanged and rejoined with a short spacer connecting the original termini, still become fluorescent. These circular permutations have altered pKa values and orientations of the chromophore with respect to a fusion partner. Furthermore, certain locations within GFP tolerate insertion of entire proteins, and conformational changes in the insert can have profound effects on the fluorescence. For example, insertions of calmodulin or a zinc finger domain in place of Tyr-145 of a yellow mutant (enhanced yellow fluorescent protein) of GFP result in indicator proteins whose fluorescence can be enhanced severalfold upon metal binding. The calmodulin graft into enhanced yellow fluorescent protein can monitor cytosolic Ca 2+ in single mammalian cells. The tolerance of GFPs for circular permutations and insertions shows the folding process is surprisingly robust and offers a new strategy for creating genetically encodable, physiological indicators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Self-citationThe scanning model for translation: an update.
Kozak, M. (1989) · The Journal of cell biology · doi:10.1083/jcb.108.2.229 · Cited by 3,486
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Self-citationVisualizing secretion and synaptic transmission with pH-sensitive green fluorescent proteins
Miesenböck, G., De Angelis, D. A., & Rothman, J. E. (1998) · Nature · doi:10.1038/28190 · Cited by 2,563
Crystal Structure of the Aequorea victoria Green Fluorescent Protein
Ormö, M., Cubitt, A. B., Kallio, K., Gross, L. A., Tsien, R. Y., & Remington, S. J. (1996) · Science · doi:10.1126/science.273.5280.1392 · Cited by 2,242
Self-citationHeim, R., Cubitt, A. B., & Tsien, R. Y. (1995) · Nature · doi:10.1038/373663b0 · Cited by 1,782
Self-citationLlopis, J., McCaffery, J. M., Miyawaki, A., Farquhar, M. G., & Tsien, R. Y. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.12.6803 · Cited by 1,130
Self-citationUltra-fast excited state dynamics in green fluorescent protein: multiple states and proton transfer.
Chattoraj, M., King, B. A., Bublitz, G. U., & Boxer, S. G. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.16.8362 · Cited by 875
Dynamic and quantitative Ca 2+ measurements using improved cameleons
Miyawaki, A., Griesbeck, O., Heim, R., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2135 · Cited by 823
Self-citationChristy, B. A., Lau, L. F., & Nathans, D. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.21.7857 · Cited by 706
Yang, T.-T., Cheng, L., & Kain, S. R. (1996) · Nucleic Acids Research · doi:10.1093/nar/24.22.4592 · Cited by 441
A Genetically Encoded Optical Probe of Membrane Voltage
Siegel, M. S., & Isacoff, E. Y. (1997) · Neuron · doi:10.1016/s0896-6273(00)80955-1 · Cited by 430
Structural basis of spectral shifts in the yellow-emission variants of green fluorescent protein
Wachter, R. M., Elsliger, M.-A., Kallio, K., Hanson, G. T., & Remington, S. J. (1998) · Structure · doi:10.1016/s0969-2126(98)00127-0 · Cited by 417
Romoser, V. A., Hinkle, P. M., & Persechini, A. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.20.13270 · Cited by 396
Pelletier, J. N., Campbell-Valois, F.-X., & Michnick, S. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.21.12141 · Cited by 382
Rossi, F., Charlton, C. A., & Blau, H. M. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.16.8405 · Cited by 322
Structural and Spectral Response of Green Fluorescent Protein Variants to Changes in pH,
Elsliger, M.-A., Wachter, R. M., Hanson, G. T., Kallio, K., & Remington, S. J. (1999) · Biochemistry · doi:10.1021/bi9902182 · Cited by 319
Calcium as a cellular regulator
Carafoli, E., & Klee, C. B. (1999) · Cited by 314
Sensitivity of the yellow variant of green fluorescent protein to halides and nitrate
Wachter, R. M., & James Remington, S. (1999) · Current Biology · doi:10.1016/s0960-9822(99)80408-4 · Cited by 177
Green fluorescent protein as a scaffold for intracellular presentation of peptides
Abedi, M. R., Caponigro, G., & Kamb, A. (1998) · Nucleic Acids Research · doi:10.1093/nar/26.2.623 · Cited by 160
Novel fluorescent indicator proteins for monitoring free intracellular Ca2+
Persechini, A., Lynch, J. A., & Romoser, V. A. (1997) · Cell Calcium · doi:10.1016/s0143-4160(97)90014-2 · Cited by 117
Interactive properties of calmodulin
Cox, J. A. (1988) · Biochemical Journal · doi:10.1042/bj2490621 · Cited by 109
Circular permutation of polypeptide chains: Implications for protein folding and stability
Heinemann, U., & Hahn, M. G. (1995) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(95)00013-5 · Cited by 93
Deletion mapping of the Aequorea victoria green fluorescent protein
Dopf, J., & Horiagon, T. M. (1996) · Gene · doi:10.1016/0378-1119(95)00692-3 · Cited by 86
Arvola, M., & KEINÄNEN, K. P. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.26.15527 · Cited by 82
Cited by
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Self-citationFluorescent Sensors for Measuring Metal Ions in Living Systems
Carter, K. P., Young, A. M., & Palmer, A. E. (2014) · Chemical Reviews · doi:10.1021/cr400546e · Cited by 2,451
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
A monomeric red fluorescent protein
Campbell, R. E., Tour, O., Palmer, A. E., Steinbach, P. A., Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082243699 · Cited by 2,365
Self-citation
Metadata
- Authors
- Baird, G. S., Zacharias, D. A., & Tsien, R. Y.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-09-28
- Volume
- 96
- Issue
- 20
- Pages
- 11241-11246
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2157199084
- Cited by
- 961
- References
- 25
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.