Cited by 402Microtubule and mitosis dynamicsForce Microscopy Techniques and ApplicationsCellular Mechanics and Interactions

Myosin-V stepping kinetics: A molecular model for processivity

Open access
Rief, Matthias, Rock, Ronald S., Mehta, Amit D., Mooseker, Mark S., Cheney, Richard E., Spudich, James A.·2000·Proceedings of the National Academy of Sciences

Abstract

Myosin-V is a molecular motor that moves processively along its actin track. We have used a feedback-enhanced optical trap to examine the stepping kinetics of this movement. By analyzing the distribution of time periods separating discrete approximately 36-nm mechanical steps, we characterize the number and duration of rate-limiting biochemical transitions preceding each such step. These data show that myosin-V is a tightly coupled motor whose cycle time is limited by ADP release. On the basis of these results, we propose a model for myosin-V processivity.

Integrity signals

Registry

Crossref · 10.1073/pnas.97.17.9482

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other molecular motors, such as myosins V and VI, are processive.

    “Other molecular motors, such as myosins V and VI are also processive (34-36”

    From Stepping and Stretching (2003) · cites this paper as [35]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 28 · Cited by 402

Authors
Rief, M., Rock, R. S., Mehta, A. D., Mooseker, M. S., Cheney, R. E., & Spudich, J. A.
Affiliations
University of North Carolina at Chapel Hill (US)
Venue
Proceedings of the National Academy of Sciences
Published
2000-08-15
Volume
97
Issue
17
Pages
9482-9486
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2055870007
Cited by
402
References
28
Citations by year
2026: 1 · 2025: 4 · 2024: 7 · 2023: 3 · 2022: 12 · 2021: 3 · 2020: 9 · 2019: 6 · 2018: 10 · 2017: 7 · 2016: 9 · 2015: 13 · 2014: 16 · 2013: 9 · 2012: 15
FWCI
9.07
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
  • UNC Libraries
Funders
  • National Institute on Deafness and Other Communication Disorders (R01DC003299, R29DC003299, DC03299)
  • National Institute of General Medical Sciences (R01GM033289, GM33289)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
Keywords
myosin V, molecular motors, processivity, actin, ADP release, optical tweezers
MeSH terms
Actins, Adenosine Diphosphate, Adenosine Triphosphate, Animals, Brain, Calmodulin-Binding Proteins, Chickens, Feedback, Kinetics, Lasers, Microspheres, Models, Biological, Movement, Nerve Tissue Proteins, Molecular Motor Proteins, Myosin Type V

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review