Kinetics of Bilirubin Transfer between Serum Albumin and Membrane Vesicles
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Unconjugated bilirubin is transported in the plasma bound primarily to serum albumin, from which it is taken up and metabolized by the liver. To better characterize the mechanism of bilirubin delivery to the hepatocyte, stopped-flow techniques were utilized to study the kinetics of bilirubin transfer between serum albumin and both model phospholipid and native hepatocyte plasma membrane vesicles. The transfer process was best described by a single exponential function, with rate constants of 0.93 +/- 0.04, 0.61 +/- 0.03, and 0.10 +/- 0.01 s-1 (+/- S.D.) at 25 degrees C for human, rat, and bovine serum albumins, respectively. The observed variations in rate with respect to donor and acceptor concentrations provide strong evidence for the diffusional transfer of free bilirubin. Thermodynamic analysis suggests that the binding site on bovine serum albumin demonstrates higher specificity for the bilirubin molecule than that on human or rat serum albumin, which exhibit similar binding characteristics. Kinetic analysis of bilirubin transfer from rat serum albumin to isolated rat basolateral liver plasma membranes indicates that the delivery of albumin-bound bilirubin to the hepatocyte surface occurs via aqueous diffusion, rather than a collisional process, thereby mitigating against the presence of an "albumin receptor."
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
pH gradients across phospholipid membranes caused by fast flip-flop of un-ionized fatty acids.
Kamp, F., & Hamilton, J. A. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.23.11367 · Cited by 299
Forker, L. E., & Luxon, B. A. (1985) · Hepatology · doi:10.1002/hep.1840050630 · Cited by 18
Cited by
Doré, S., Takahashi, M., Ferris, C. D., Hester, L. D., Guastella, D., & Snyder, S. H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2445 · Cited by 699
Gouva, C., Nikolopoulos, P., Ioannidis, J. P. A., & Siamopoulos, K. C. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00797.x · Cited by 410
A Bilirubin-Inducible Fluorescent Protein from Eel Muscle
Kumagai, A., Ando, R., Miyatake, H., Greimel, P., Kobayashi, T., Hirabayashi, Y., Shimogori, T., & Miyawaki, A. (2013) · Cell · doi:10.1016/j.cell.2013.05.038 · Cited by 338
Removal of P-Cresol Sulfate by Hemodialysis
Martinez, A. W., Recht, N. S., Hostetter, T. H., & Meyer, T. W. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2005030310 · Cited by 262
Boyer, J. L. (2013) · Comprehensive Physiology · doi:10.1002/j.2040-4603.2013.tb00519.x · Cited by 124
Metadata
- Authors
- Zucker, S. D., Goessling, W., & Gollan, J. L.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 270
- Issue
- 3
- Pages
- 1074-1081
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2024960351
- Cited by
- 66
- References
- 2
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.