The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
HLA-E Allelic Variants
Open accessAbstract
Previous studies of HLA-E allelic polymorphism have indicated that balancing selection may be acting to maintain two major alleles in most populations, indicating that a functional difference may exist between the alleles. The alleles differ at only one amino acid position, where an arginine at position 107 in HLA-E*0101 (E(R)) is replaced by a glycine in HLA-E*0103 (E(G)). To investigate possible functional differences, we have undertaken a study of the physical and biochemical properties of these two proteins. By comparing expression levels, we found that whereas steady-state protein levels were similar, the two alleles did in fact differ with respect to cell surface levels. To help explain this difference, we undertook studies of the relative differences in peptide affinity, complex stability, and three-dimensional structure between the alleles. The crystal structures for HLA-E(G) complexed with two distinct peptides were determined, and both were compared with the HLA-E(R) structure. No significant differences in the structure of HLA-E were induced as a result of binding different peptides or by the allelic substitution at position 107. However, there were clear differences in the relative affinity for peptide of each heavy chain, which correlated with and may be explained by differences between their thermal stabilities. These differences were completely consistent with the relative levels of the HLA-E alleles on the cell surface and may indeed correlate with functional differences. This in turn may help explain the apparent balancing selection acting on this locus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[20] Processing of X-ray diffraction data collected in oscillation mode
Otwinowski, Z., & Minor, W. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)76066-x · Cited by 33,475
PROCHECK: a program to check the stereochemical quality of protein structures
Laskowski, R. A., MacArthur, M. W., Moss, D. S., & Thornton, J. M. (1993) · Journal of Applied Crystallography · doi:10.1107/s0021889892009944 · Cited by 24,581
STRUCTURE, FUNCTION, AND DIVERSITY OF CLASS I MAJOR HISTOCOMPATIBILITY COMPLEX MOLECULES
Bjorkman, P. J., & Parham, P. (1990) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.59.070190.001345 · Cited by 700
Cited by
Imprint of human cytomegalovirus infection on the NK cell receptor repertoire
Gumá, M., Angulo, A., Vilches, C., Gómez-Lozano, N., Malats, N., & López-Botet, M. (2004) · Blood · doi:10.1182/blood-2004-05-2058 · Cited by 865
Activation of NK Cells by an Endocytosed Receptor for Soluble HLA-G
Rajagopalan, S., Bryceson, Y. T., Kuppusamy, S. P., Geraghty, D. E., Meer, A. V. D., Joosten, I., & Long, E. O. (2005) · PLoS Biology · doi:10.1371/journal.pbio.0040009 · Cited by 353
Self-citationHLA associations and HLA sharing in recurrent miscarriage: A systematic review and meta-analysis
Meuleman, T., Lashley, L. E. L. O., Dekkers, O. M., van Lith, J. M. M., Claas, F. H. J., & Bloemenkamp, K. W. M. (2015) · Human Immunology · doi:10.1016/j.humimm.2015.02.004 · Cited by 89
Metadata
- Authors
- Strong, R. K., Holmes, M. A., Li, P., Braun, L., Lee, N., & Geraghty, D. E.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 2003-02
- Volume
- 278
- Issue
- 7
- Pages
- 5082-5090
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2070214550
- Cited by
- 308
- References
- 3
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HLA-E Allelic Variants. https://app.cochat.ai/papers/10.1074/jbc.m208268200
- The paper
- Strong, R. K., Holmes, M. A., Li, P., Braun, L., Lee, N., & Geraghty, D. E. (2003). HLA-E Allelic Variants. Journal of Biological Chemistry. https://doi.org/10.1074/jbc.m208268200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.