Cited by 316Hemoglobin structure and functionRetinal Development and DisordersHeme Oxygenase-1 and Carbon Monoxide

How Does the Eye Breathe?

Open access
Schmidt, Marc, Giessl, Andreas, Laufs, Tilmann, Hankeln, Thomas, Wolfrum, Uwe, Burmester, Thorsten·2003·Journal of Biological Chemistry

Abstract

Visual performance of the vertebrate eye requires large amounts of oxygen, and thus the retina is one of the highest oxygen-consuming tissues of the body. Here we show that neuroglobin, a neuron-specific respiratory protein distantly related to hemoglobin and myoglobin, is present at high amounts in the mouse retina (approximately 100 microm). The estimated concentration of neuroglobin in the retina is thus about 100-fold higher than in the brain and is in the same range as that of myoglobin in the muscle. Neuroglobin is expressed in all neurons of the retina but not in the retinal pigment epithelium. Neuroglobin mRNA was detected in the perikarya of the nuclear and ganglion layers of the neuronal retina, whereas the protein was present mainly in the plexiform layers and in the ellipsoid region of photoreceptor inner segment. The distribution of neuroglobin correlates with the subcellular localization of mitochondria and with the relative oxygen demands, as the plexiform layers and the inner segment consume most of the retinal oxygen. These findings suggest that neuroglobin supplies oxygen to the retina, similar to myoglobin in the myocardium and the skeletal muscle.

Integrity signals

Registry

Crossref · 10.1074/jbc.m209909200

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Physiological levels of Ngb have been reported to be between 1 μM in the brain and up to 100 μM in the retina.

    “Physiological levels of Ngb have been reported to be between 1 μM in the brain and up to 100 μM in the retina [63, 64].”

    From Mechanisms of nitrite bioactivation (2014) · cites this paper as [63]

The citation lists haven’t been fetched yet

References 34 · Cited by 316

Authors
Schmidt, M., Giessl, A., Laufs, T., Hankeln, T., Wolfrum, U., & Burmester, T.
Affiliations
Johannes Gutenberg University Mainz (DE)
Corresponding author
Burmester, Thorsten
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
2003-01
Volume
278
Issue
3
Pages
1932-1935
ISSN
0021-9258 (ISSN-L)
OpenAlex
W2001325871
Cited by
316
References
34
Citations by year
2026: 4 · 2025: 5 · 2024: 7 · 2023: 6 · 2022: 9 · 2021: 11 · 2020: 4 · 2019: 7 · 2018: 5 · 2017: 15 · 2016: 11 · 2015: 19 · 2014: 11 · 2013: 17 · 2012: 15
FWCI
7.02
Type
journal article
Language
en
Open access
Locations
  • Journal of Biological Chemistry (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Hemoglobin structure and function
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Heme Oxygenase-1 and Carbon Monoxide
Keywords
neuroglobin, retina, retinal oxygen consumption, mitochondrial localization, photoreceptor inner segment, plexiform layer, retinal ganglion cells, retinal neurons, subcellular protein distribution, oxygen-binding proteins
MeSH terms
Neuroglobin, Animals, Globins, Mice, Inbred BALB C, Mice, Inbred C57BL, Nerve Tissue Proteins, Oxygen, Retina, Photoreceptor Cells, Vertebrate, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review