CoChat

Intact-protein-based High-resolution Three-dimensional Quantitative Analysis System for Proteome Profiling of Biological Fluids

Open access
Wang, Hong, Clouthier, Shawn G., Galchev, Vladimir, Misek, David E., Duffner, Ulrich, Min, Chang-Ki, Zhao, Rong, Tra, John, Omenn, Gilbert S., Ferrara, James L.M., Hanash, Samir M. · 2005 · Molecular & Cellular Proteomics
Cited by 130

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The substantial complexity and vast dynamic range of protein abundance in biological fluids, notably serum and plasma, present a formidable challenge for comprehensive protein analysis. Integration of multiple technologies is required to achieve high-resolution and high-sensitivity proteomics analysis of biological fluids. We have implemented an orthogonal three-dimensional intact-protein analysis system (IPAS), coupled with protein tagging and immunodepletion of abundant proteins, to quantitatively profile the human plasma proteome. Following immunodepletion, plasma proteins in each of paired samples are concentrated and labeled with a different Cy dye, before mixing. Proteins are subsequently separated in three dimensions according to their charge, hydrophobicity, and molecular mass. Differences in the abundance of resolved proteins are determined based on Cy dye ratios. We have applied this strategy to profile the plasma proteome for changes that occur with acute graft-versus-host disease (GVHD), following allogeneic bone marrow transplantation (BMT). Using capillary HPLC ESI Q-TOF MS, we identified 75 proteins in the micromolar to femtomolar range that exhibited quantitative differences between the pre- and post-GVHD samples. These proteins included serum amyloid A, apolipoproteins A-I/A-IV, and complement C3 that are well-known acute-phase reactants likely reflecting the post-BMT inflammatory state. In addition, we identified some potentially interesting immunologically relevant molecules including vitamin D-binding protein, fetuin, vitronectin, proline-rich protein 3 and 4, integrin-alpha, and leukocyte antigen CD97. IPAS provides a combination of comprehensive profiling and quantitative analysis, with a substantial dynamic range, for disease-related applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.m400126-mcp200

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 130

Metadata

Authors
Wang, H., Clouthier, S. G., Galchev, V., Misek, D. E., Duffner, U., Min, C.-K., Zhao, R., Tra, J., Omenn, G. S., Ferrara, J. L. M., & Hanash, S. M.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2005-05
Volume
4
Issue
5
Pages
618-625
ISSN
1535-9476 (ISSN-L)
OpenAlex
W2167977108
Cited by
130
References
1
FWCI
7.81
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intact-protein-based High-resolution Three-dimensional Quantitative Analysis System for Proteome Profiling of Biological Fluids. https://app.cochat.ai/papers/10.1074/mcp.m400126-mcp200
The paper
Wang, H., Clouthier, S. G., Galchev, V., Misek, D. E., Duffner, U., Min, C.-K., Zhao, R., Tra, J., Omenn, G. S., Ferrara, J. L. M., & Hanash, S. M. (2005). Intact-protein-based High-resolution Three-dimensional Quantitative Analysis System for Proteome Profiling of Biological Fluids. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m400126-mcp200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.