CoChat

Improving Protein Identification Using Complementary Fragmentation Techniques in Fourier Transform Mass Spectrometry

Open access
Nielsen, Michael L., Savitski, Mikhail M., Zubarev, Roman A. · 2005 · Molecular & Cellular Proteomics
Cited by 139

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Identification of proteins by MS/MS is performed by matching experimental mass spectra against calculated spectra of all possible peptides in a protein data base. The search engine assigns each spectrum a score indicating how well the experimental data complies with the expected one; a higher score means increased confidence in the identification. One problem is the false-positive identifications, which arise from incomplete data as well as from the presence of misleading ions in experimental mass spectra due to gas-phase reactions, stray ions, contaminants, and electronic noise. We employed a novel technique of reduction of false positives that is based on a combined use of orthogonal fragmentation techniques electron capture dissociation (ECD) and collisionally activated dissociation (CAD). Since ECD and CAD exhibit many complementary properties, their combined use greatly increased the analysis specificity, which was further strengthened by the high mass accuracy (approximately 1 ppm) afforded by Fourier transform mass spectrometry. The utility of this approach is demonstrated on a whole cell lysate from Escherichia coli. Analysis was made using the data-dependent acquisition mode. Extraction of complementary sequence information was performed prior to data base search using in-house written software. Only masses involved in complementary pairs in the MS/MS spectrum from the same or orthogonal fragmentation techniques were submitted to the data base search. ECD/CAD identified twice as many proteins at a fixed statistically significant confidence level with on average a 64% higher Mascot score. The confidence in protein identification was hereby increased by more than 1 order of magnitude. The combined ECD/CAD searches were on average 20% faster than CAD-only searches. A specially developed test with scrambled MS/MS data revealed that the amount of false-positive identifications was dramatically reduced by the combined use of CAD and ECD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/mcp.t400022-mcp200

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 139

Metadata

Authors
Nielsen, M. L., Savitski, M. M., & Zubarev, R. A.
Venue
Molecular & Cellular Proteomics
Publisher
Elsevier BV
Published
2005-06
Volume
4
Issue
6
Pages
835-845
ISSN
1535-9476 (ISSN-L)
OpenAlex
W2157115248
Cited by
139
References
4
FWCI
7.37
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving Protein Identification Using Complementary Fragmentation Techniques in Fourier Transform Mass Spectrometry. https://app.cochat.ai/papers/10.1074/mcp.t400022-mcp200
The paper
Nielsen, M. L., Savitski, M. M., & Zubarev, R. A. (2005). Improving Protein Identification Using Complementary Fragmentation Techniques in Fourier Transform Mass Spectrometry. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.t400022-mcp200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.