Assessment of the heart-rate method for determining energy expenditure in man, using a whole-body calorimeter
Open accessThe DOI matches its Crossref record.
Abstract
1. The heart-rate (HR) method for determining the energy expenditure of free-living subjects has been evaluated using a whole-body calorimete in which individuals lived continuously for 27 h while carrying out normal daily activities. Eight male volunteers each occupied the calorimeter on at least two occasions when HR and energy expenditure were measured continously. 2. After each session in the calorimeter a calibration was obtained using standard techniques by determining HR and heat production (HP) over periods of 10–15 min at several levels of activity. Energy expenditure in the calorimeter was then predicted, by each of five methods, from the mean HR in the calorimeter. Additionally, one session in the calorimeter was used to obtain a calibration and was used for predicting the subject's energy expenditure while in the calorimeter on other occasions. 3. Standard methods of prediction using one calibration point at rest and several points during activity were unreliable for predicting the energy expenditure of an individual. The 24 h HR was at the lower end of the calibration scale and there were considerable over-estimates or underestimates of energy expenditure, particularly during the night when the mean (±SD) difference between the actual and predicted HP was −66±38±6%. A linear regression fitted to points at the lower levels of activity improved the prediction of 24 h HP while a logistic plot reduced the error even further. The best estimate of energy expenditure was that obtained from a calibration over 24 h within the calorimeter; the mean (±SD) difference between the actual and predicted 24 h HP was +3+10.5% for light activity and −3±6.7% for moderate activity. Thus current procedures for calibrating subjects may lead to large errors which could be reduced by using a respiratory chamber.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart Rate Monitoring: Applications and Limitations
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,166
Assessment of Energy Expenditure and Fuel Utilization in Man
Jequier, E., Acheson, K., & Schutz, Y. (1987) · Annual Review of Nutrition · doi:10.1146/annurev.nu.07.070187.001155 · Cited by 531
Energy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry
Spurr, G., Prentice, A., Murgatroyd, P., Goldberg, G., Reina, J., & Christman, N. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.3.552 · Cited by 414
Measurement of energy expenditure
Levine, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005800 · Cited by 401
Ceesay, S. M., Prentice, A. M., Day, K. C., Murgatroyd, P. R., Goldberg, G. R., Scott, W., & Spurr, G. B. (1989) · British Journal of Nutrition · doi:10.1079/bjn19890107 · Cited by 318
Metadata
- Authors
- Dauncey, M. J., & James, W. P. T.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 1979-07
- Volume
- 42
- Issue
- 1
- Pages
- 1-13
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2086476979
- Cited by
- 99
- References
- 0
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of the heart-rate method for determining energy expenditure in man, using a whole-body calorimeter. https://app.cochat.ai/papers/10.1079/bjn19790084
- The paper
- Dauncey, M. J., & James, W. P. T. (1979). Assessment of the heart-rate method for determining energy expenditure in man, using a whole-body calorimeter. British Journal of Nutrition. https://doi.org/10.1079/bjn19790084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.