Evaluation of a foot-to-foot bioelectrical impedance analyser in highly active, moderately active and less active young men
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The Tanita TBF-305 (Tanita Corp., Tokyo, Japan) is a commercially available foot-to-foot bioelectrical impedance analysis (BIA) system. The manufacturer-supplied equations incorporate gender, mass, height, activity category and a measured impedance value to determine % body fat (BF). The purpose of the present study was to determine whether the manufacturer-supplied ‘adult’ and ‘athlete’ equations provided an accurate estimate of % BF for a group of young men with varying activity levels. Fifty-seven men (18–35 years old) were categorized into the following groups: (1) highly active (HA) (≥10·0 h aerobic activity/week); (2) moderately active (MA) (2·5–10·0 h aerobic activity/week); (3) less active (LA) (<2·5 h aerobic activity/week). The % BF was measured using the BIA ‘athlete’ and ‘adult’ modes. After BIA measurements, residual volume was measured and hydrostatic weighing (HW) was performed. The amount of activity performed by each group was significantly different (P<0·001). No significant differences were found between the % BF determined by the ‘athlete’ mode and HW for HA (P=0·309) and MA (P=0·091). However, a significant difference was found for LA (P=0·001). The % BF determined by the ‘adult’ mode and HW was not different for LA (P=0·395), but was significantly different for MA (P<0·001) and HA (P<0·001). The choice of activity mode on the foot-to-foot BIA significantly alters prediction of % BF. With careful selection of activity mode, there was no statistical difference between % BF determined by HW and the BIA, but the range of individual error scores was large.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
Cited by
Is bioelectrical impedance accurate for use in large epidemiological studies?
Dehghan, M., & Merchant, A. T. (2008) · Nutrition Journal · doi:10.1186/1475-2891-7-26 · Cited by 505
Effects of 8 wk of 16:8 Time-restricted Eating in Male Middle- and Long-Distance Runners
BRADY, A. J., LANGTON, H. M., MULLIGAN, M., & EGAN, B. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002488 · Cited by 60
Effects of tibolone on body composition in postmenopausal women: a 1-year follow up study
Boyanov, M. A., & Shinkov, A. D. (2005) · Maturitas · doi:10.1016/j.maturitas.2004.09.003 · Cited by 24
Correction of Hypothyroidism Seems to Have No Effect on Body Fat
Bakiner, O., Bozkirli, E., Ersozlu Bozkirli, E. D., & Ozsahin, K. (2013) · International Journal of Endocrinology · doi:10.1155/2013/576794 · Cited by 14
“Bioelectrical impedance analysis system (BIA) is an easy and a cheap method which helps to identify different body compartments: body lipid percentage, fat-free bodymass, and total body fluid [15].”
Background
Metadata
- Authors
- Swartz, A. M., Evans, M. J., King, G. A., & Thompson, D. L.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2002-08
- Volume
- 88
- Issue
- 2
- Pages
- 205-210
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2058069428
- Cited by
- 46
- References
- 2
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.