This survey focused on clinical reports of polyethylene wear and osteolysis in total hip replacements. With regard to documentation of clinical wear-rates, 57 publications were reduced to an analysis of 8 reports of THR series, including the incidence of osteolysis. A direct correlation was found among volumetric wear-rates, incidence of osteolysis and revision rates in THR concepts of the 1983-1987 era. As volumetric wear rate increased, the incidence of osteolysis and revision rates increased. With regard to our grading system for volumetric wear, with follow-up in the 4-15 year range, osteolysis was rare in group A (wear = 0-80 mm3/year), ranging from 6% to 31% in group B (wear 40-80 mm3/year) and from 21% to 100% in group C (wear > 140 mm3/year). With regard to cup design, the optimal low-wear group had mainly cemented polyethylene cups with 22 and 28 mm head sizes. The mid-wear group B had metal-backed cemented and uncemented cups, with 28 mm head size, and the high-risk group C had only uncemented, metal-backed cups, with the highest wear in the 32 mm head size. Less than 10 years of follow-up did not distinguish adequately between different designs of THR, except in a few cases which had early failures due to material or design deficiencies. Overall, the cemented all-polyethylene cup combined with the smaller ball head proved to be better.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
Yamada, C., Ho, A., Akkaoui, J., Garcia, C., Duarte, C., & Movila, A. (2021) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2021.111503 · Cited by 33
Metadata
- Authors
- Oparaugo, P. C., Clarke, I. C., Malchau, H., & Herberts, P.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 2001-01
- Volume
- 72
- Issue
- 1
- Pages
- 22-28
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2155866152
- Cited by
- 166
- References
- 0
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: A survey of 8 reports in the literature. https://app.cochat.ai/papers/10.1080/000164701753606644
- The paper
- Oparaugo, P. C., Clarke, I. C., Malchau, H., & Herberts, P. (2001). Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: A survey of 8 reports in the literature. Acta Orthopaedica Scandinavica. https://doi.org/10.1080/000164701753606644
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.