CoChat

Positioner–a method for preventing sleep apnea

Loord, Helena, Hultcrantz, Elisabeth · 2007 · Acta Oto-Laryngologica

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

CONCLUSIONS: A 'Positioner' preventing sleeping on the back can effectively reduce obstructive sleep apnea (OSA), but not always snoring for patients with long-term OSA. By preference, the device should be used for younger snorers without OSA as a training tool to avoid sleeping on the back. Instructions and support by a nurse are necessary for compliance. OBJECTIVES: Snoring is a progressive condition with a prevalence of 25-30% among the adult male population. Long-term snoring seems to be the basis for apneas caused by vibration damage to the pharyngeal tissue. Patients with OSA often have more apneas in the supine position than in the lateral position. Preventing sleeping on the back is a way to treat OSA. The aim of this study was to evaluate the efficacy and comfort of a recently developed Positioner. SUBJECTS AND METHODS: A total of 23 patients diagnosed with positional sleep apnea (AHI>15 in supine position and AHI<5 in lateral position), were included. The Positioner--a soft vest, attached to a board placed under the pillow, makes it impossible for the patient to sleep on his back. It was fitted and tried out individually. Patients answered sleep questionnaires and kept sleep diaries before beginning use. After 3 months, a new sleep study was done while using the Positioner and new questionnaires were filled out. RESULTS: Eighteen patients (5 women and 13 men) completed the study. The rest could not tolerate being strapped into the Positioner. Of those participating, 61% demonstrated a decrease of AHI to<10 using the Positioner. The Epworth Sleepiness Scale (ESS) decreased from a mean of 12.3 to 10.2. Half of the patients snored more frequently with the Positioner. The evaluation of comfort showed that minor adjustments are desirable.

Overview

Integrity signals

Registry

Crossref · 10.1080/00016480601089390

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 16 references

Cited by

See all 49

Metadata

Authors
Loord, H., & Hultcrantz, E.
Affiliations
  • Linköping University Hospital (SE)
  • Linköping University (SE)
Venue
Acta Oto-Laryngologica
Published
2007-01
Volume
127
Issue
8
Pages
861-868
ISSN
  • 0001-6489 (ISSN-L)
  • 1651-2251
OpenAlex
W2097474033
Cited by
49
References
16
Citations by year
2025: 1 · 2023: 3 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 2 · 2016: 1 · 2015: 4 · 2014: 6 · 2013: 5 · 2012: 6
FWCI
1.33
Type
journal article
Language
en
Open access
closed
Locations
  • Acta Oto-Laryngologica (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
Keywords
positional obstructive sleep apnea, obstructive sleep apnea, snoring, apnea-hypopnea index, daytime sleepiness, device comfort, medication adherence, nursing support
MeSH terms
Equipment Design, Female, Follow-Up Studies, Humans, Male, Middle Aged, Patient Compliance, Posture, Surveys and Questionnaires, Severity of Illness Index, Sleep Apnea Syndromes, Snoring, Prevalence, Treatment Outcome, Physical Therapy Modalities

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Positioner–a method for preventing sleep apnea. https://app.cochat.ai/papers/10.1080/00016480601089390
The paper
Loord, H., & Hultcrantz, E. (2007). Positioner–a method for preventing sleep apnea. Acta Oto-Laryngologica. https://doi.org/10.1080/00016480601089390

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.