Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 681

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities

Chatrian, G. E., Lettich, E., Nelson, P. L.·1985·American Journal of EEG Technology

Abstract

.An 81-electrode system is described which is designed for topographic studies of spontaneous and evoked EEG activities. This method combines the standard leads of the International 10–20 System with supplementary electrodes applied midway between leads of the 10–20 system or electrodes in turn situated between 10–20 leads. Auxiliary electrode designations refer to the underlying brain areas and to adjacent leads of the 10–20 method. The utilization of this “10% system” is suggested to promote standardization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00029238.1985.11080163

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 681

Metadata

Authors
Chatrian, G. E., Lettich, E., & Nelson, P. L.
Venue
American Journal of EEG Technology
Published
1985-06
Volume
25
Issue
2
Pages
83-92
ISSN
  • 0002-9238 (ISSN-L)
  • 2375-8600
OpenAlex
W2336274017
Cited by
681
References
5
FWCI
1.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities. https://app.cochat.ai/papers/10.1080/00029238.1985.11080163
The paper
Chatrian, G. E., Lettich, E., & Nelson, P. L. (1985). Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities. American Journal of EEG Technology. https://doi.org/10.1080/00029238.1985.11080163

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.