The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities
Abstract
.An 81-electrode system is described which is designed for topographic studies of spontaneous and evoked EEG activities. This method combines the standard leads of the International 10–20 System with supplementary electrodes applied midway between leads of the 10–20 system or electrodes in turn situated between 10–20 leads. Auxiliary electrode designations refer to the underlying brain areas and to adjacent leads of the 10–20 method. The utilization of this “10% system” is suggested to promote standardization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Multidisciplinary perspectives in event-related brain potential research
Valciukas, J. (1981) · Environmental Research · doi:10.1016/0013-9351(81)90173-0 · Cited by 256
CHATRIAN, G. E., CANFIELD, R. C., KNAUSS, T. A., & LETTICH, E. (1975) · Neurology · doi:10.1212/wnl.25.8.745 · Cited by 192
Self-citationThe anterior temporal electrode and the ten-twenty system
Silverman, D., Bernard, R., & Mellies, M. (1960) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(60)90119-x · Cited by 115
Noonan, B. D., Wilkus, R. J., Chatrian, G. E., & Lettich, E. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90025-4 · Cited by 25
Self-citation
Cited by
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909
Jurcak, V., Tsuzuki, D., & Dan, I. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.024 · Cited by 1,489
Hillman, C. H., Pontifex, M. B., Raine, L. B., Castelli, D. M., Hall, E. E., & Kramer, A. F. (2009) · Neuroscience · doi:10.1016/j.neuroscience.2009.01.057 · Cited by 845
Effects of the FITKids Randomized Controlled Trial on Executive Control and Brain Function
Hillman, C. H., Pontifex, M. B., Castelli, D. M., Khan, N. A., Raine, L. B., Scudder, M. R., Drollette, E. S., Moore, R. D., Wu, C.-T., & Kamijo, K. (2014) · Pediatrics · doi:10.1542/peds.2013-3219 · Cited by 661
Virtual spatial registration of stand-alone fNIRS data to MNI space
Tsuzuki, D., Jurcak, V., Singh, A. K., Okamoto, M., Watanabe, E., & Dan, I. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.043 · Cited by 630
Metadata
- Authors
- Chatrian, G. E., Lettich, E., & Nelson, P. L.
- Venue
- American Journal of EEG Technology
- Publisher
- Informa UK Limited
- Published
- 1985-06
- Volume
- 25
- Issue
- 2
- Pages
- 83-92
- ISSN
- 0002-9238 (ISSN-L)
- 2375-8600
- OpenAlex
- W2336274017
- Cited by
- 681
- References
- 5
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities. https://app.cochat.ai/papers/10.1080/00029238.1985.11080163
- The paper
- Chatrian, G. E., Lettich, E., & Nelson, P. L. (1985). Ten Percent Electrode System for Topographic Studies of Spontaneous and Evoked EEG Activities. American Journal of EEG Technology. https://doi.org/10.1080/00029238.1985.11080163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.