Fluorescence Quantum Yields of Tryptophan and Tyrosine
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Fluorescence quantum yields (Q) for tyrosine, tryptophan, and phenylalanine in water at 23° determined by the comparative method using a quinine standard were found to be 0.14, 0.13, and 0.024, respectively. Similar values were obtained with phenol as the standard. The numbers are much lower than those literature values which have been widely used to calculate protein fluorescence quantum yields. Possible reasons for the discrepancies are discussed. The quantum yields of isomeric tyrosines and fluorophenylalanines are also reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Melhuish, W. H. (1961) · The Journal of Physical Chemistry · doi:10.1021/j100820a009 · Cited by 1,847
Correction of fluorescence spectra and measurement of fluorescence quantum efficiency
Parker, C. A., & Rees, W. T. (1960) · The Analyst · doi:10.1039/an9608500587 · Cited by 1,280
Ultraviolet fluorescence of the aromatic amino acids
Teale, F. W. J., & Weber, G. (1957) · Biochemical Journal · doi:10.1042/bj0650476 · Cited by 769
Determination of the absolute quantum yield of fluorescent solutions
Weber, G., & Teale, F. W. J. (1957) · Transactions of the Faraday Society · doi:10.1039/tf9575300646 · Cited by 665
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Binding of transition metal ions to albumin: Sites, affinities and rates
Bal, W., Sokołowska, M., Kurowska, E., & Faller, P. (2013) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.06.018 · Cited by 489
Strong underwater adhesives made by self-assembling multi-protein nanofibres
Zhong, C., Gurry, T., Cheng, A. A., Downey, J., Deng, Z., Stultz, C. M., & Lu, T. K. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.199 · Cited by 442
Fluorescence lifetime imaging ophthalmoscopy
Dysli, C., Wolf, S., Berezin, M. Y., Sauer, L., Hammer, M., & Zinkernagel, M. S. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.06.005 · Cited by 203
“Phenylalanine and tyrosine suffer from low quantum yield and poor molar absorptivity (Chen, 1967; Barrett and Elmore, 1998) with weak emission at 350 nm. Tryptophan, with its moderate molar absorptivity (5500 M 1 cm 1) (Barrett and Elmore, 1998) and decent quantum yield (F ¼ 0.13) (Chen,…”
BackgroundInfluential
Metadata
- Authors
- Chen, R. F.
- Venue
- Analytical Letters
- Publisher
- Informa UK Limited
- Published
- 1967-01
- Volume
- 1
- Issue
- 1
- Pages
- 35-42
- ISSN
- 0003-2719 (ISSN-L)
- 1532-236X
- OpenAlex
- W2005757429
- Cited by
- 455
- References
- 4
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.