The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
An Analysis of Heart Rate Variability
Abstract
Proceeding from a formal definition of heart rate variability, some mathematical and statistical techniques from sampling statistics and time series analysis for the analytical evaluation of heart rate variability for ergonomics purposes are presented and compared. The concept of sampling statistics gives a measure of heart rate variability, arrived at by combining two measures, which were chosen according to a definite criterion. The applicability of this measure is discussed; especially with respect to serial correlation influences when using statistical tests. The two main methods of spectral analysis—the calculation of the transformed autocovariance function and of harmonic analysis–are presented. The influences of interpolations, algorithms and physiological effects are discussed. A possible measure of heart rate variability, calculated by spectral estimates, is proposed and some results are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Respiratory sinus arrhythmia: a frequency dependent phenomenon
Angelone, A., & Coulter, N. A. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.3.479 · Cited by 441
Cited by
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Frequency domain measures of heart period variability and mortality after myocardial infarction
Bigger, J. T., Fleiss, J. L., Steinman, R. C., Rolnitzky, L. M., Kleiger, R. E., & Rottman, J. N. (1992) · Circulation · doi:10.1161/01.cir.85.1.164 · Cited by 1,712
Malik, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 850
Metadata
- Authors
- LUCZAK, H., & LAURIG, W.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1973-01
- Volume
- 16
- Issue
- 1
- Pages
- 85-97
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2076992006
- Cited by
- 224
- References
- 2
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Analysis of Heart Rate Variability. https://app.cochat.ai/papers/10.1080/00140137308924484
- The paper
- LUCZAK, H., & LAURIG, W. (1973). An Analysis of Heart Rate Variability. Ergonomics. https://doi.org/10.1080/00140137308924484
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.