Clothing ventilation, vapour resistance and permeability index: changes due to posture, movement and wind
The DOI matches its Crossref record.
Abstract
Using the trace gas diffusion method, the vapour resistance of three clothing ensembles (two permeable and one impermeable) was determined for four subjects, sitting, standing or walking at 0-3 and 09 m/s, combined with three wind speeds of <0-15, 0-7 and 41 m/s. Sitting increased vapour resistance by 12-36%, whereas walking and wind decreased the resistance by 72% and 89% when compared to standing with less than 0-15 m/s wind. Movement and wind interacted so that the higher the walking speed, the less additional effect of wind was observed. Values of the permeability index Im were calculated. Wind and movement increased Im up to a factor three for the permeable and up to a factor six for the impermeable garments. However, using a different definition of Im(I'm.), based on the convective part of the heat transfer coefficient only, resulted in higher I'm values (compared to im) which remained constant with wind and movement. It was shown that with increasing wind and movement Im will increase and approach the value of
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Personal factors in thermal comfort assessment: clothing properties and metabolic heat production
Havenith, G., Holmér, I., & Parsons, K. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00008-7 · Cited by 376
Self-citationHavenith, G., Fiala, D., Błazejczyk, K., Richards, M., Bröde, P., Holmér, I., Rintamaki, H., Benshabat, Y., & Jendritzky, G. (2012) · International Journal of Biometeorology · doi:10.1007/s00484-011-0451-4 · Cited by 350
“…movement on clothing insulation Both clothing insulation and the insulation of surface air layers are heavily influenced by changing wind speed and body movement (Havenith et al. 1990a,b, 2002, 2008, Holmér et al., 1999,Havenith and Nilsson, 2004,2005, Nielsen et al. 1985, Nilsson et al. 2000).”
BackgroundSelf-citationThermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262
“…in actual conditions incorporating effects of movement and wind (105); affecting all dry heat transfers, I T ], and (cid:2) resultant clothing vapor resistance (the vapor resistance in actual conditions incorporating effects of movement and wind (102); affecting evaporative heat transfer, R ET ].”
Self-citationMechanisms of Heat Exchange: Biophysics and Physiology
Gagge, A. P., & Gonzalez, R. R. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp040104 · Cited by 258
Wang, W., Yao, L., Cheng, C.-Y., Zhang, T., Atsumi, H., Wang, L., Wang, G., Anilionyte, O., Steiner, H., Ou, J., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601984 · Cited by 251
Metadata
- Authors
- HAVENITH, G., HEUS, R., & LOTENS, W. A.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1990-08
- Volume
- 33
- Issue
- 8
- Pages
- 989-1005
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2041467328
- Cited by
- 143
- References
- 0
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clothing ventilation, vapour resistance and permeability index: changes due to posture, movement and wind. https://app.cochat.ai/papers/10.1080/00140139008925308
- The paper
- HAVENITH, G., HEUS, R., & LOTENS, W. A. (1990). Clothing ventilation, vapour resistance and permeability index: changes due to posture, movement and wind. Ergonomics. https://doi.org/10.1080/00140139008925308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.