The DOI matches its Crossref record.
The quantification of EMG normalization error
Abstract
Electromyography (EMG) and normalized EMG have been accepted as methods of quantifying the activity level of a muscle. Normalized EMG, in conjunction with the EMG/force relationship and muscle cross-sectional area data, allows researchers to estimate the amount of muscle force exerted across a joint. An accurate description of this muscle force is a critical input to models designed to describe the risk of injury of a task. In order to be able to make statements about the relative intensity of an EMG signal, researchers who use normalization procedures take a given EMG activity level, at a known joint angle, and relate it to some reference activity level obtained at that particular joint angle. However, there have been studies where the EMG activity of an unrestricted dynamic task, such as walking, cycling, performing an occupational task, etc., has been normalized with respect to an EMG value taken during a single maximum voluntary contraction performed at one reference joint angle. This practice will render inaccurate results because at different joint angles there are changes in the portion of the muscle within the viewing area of the electrode, as well as changes in the length/tension relationship of the muscle which would cause changes in the maximum EMG value. The present study was an attempt to quantify the errors associated with normalization relative to a reference EMG value collected at an arbitrary joint position. Four subjects performed a series of controlled trunk extension exertions. As they performed these exertions the EMG activities were collected for eight trunk muscles. The task EMG values that resulted were then: (1) all normalized with respect to the maximum EMG at a single arbitrary trunk angle and (2) each normalized with respect to that specific trunk angle's maximum EMG. The results show that for the primary trunk extensors (erector spinae) large errors (greater than 75%) resulted from normalization using a single reference point and the magnitude of these errors followed consistent patterns within subjects as a function of trunk angle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ludewig, P. M., & Cook, T. M. (2000) · Physical Therapy · doi:10.1093/ptj/80.3.276 · Cited by 1,655
A comparison of knee joint motion patterns between men and women in selected athletic tasks
Malinzak, R. A., Colby, S. M., Kirkendall, D. T., Yu, B., & Garrett, W. E. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00019-5 · Cited by 777
Burden, A. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.07.004 · Cited by 717
Mathiassen, S. E., Winkel, J., & Hägg, G. M. (1995) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)00014-x · Cited by 516
Electromyographic analysis of pedaling: A review
Hug, F., & Dorel, S. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.10.010 · Cited by 358
Metadata
- Authors
- MIRKA, G. A.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1991-03
- Volume
- 34
- Issue
- 3
- Pages
- 343-352
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2020011561
- Cited by
- 227
- References
- 0
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The quantification of EMG normalization error. https://app.cochat.ai/papers/10.1080/00140139108967318
- The paper
- MIRKA, G. A. (1991). The quantification of EMG normalization error. Ergonomics. https://doi.org/10.1080/00140139108967318
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.