Robust control system design with a proportional integral observer
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A design method for a robust controller including a new type of observer called the proportional integral observer (PI observer) is proposed. The new observer differs from the conventional one by an integration path which provides additional degrees of freedom. This freedom can be used to make the observer-based controller design less sensitive to parameter variation of the system. It is shown that some of the difficulties that may arise in the exclusive pursuit of a design for the conventional observer-based controller from the point of view of system robustness are resolved in a straightforward manner using the PI observer. A systematic robustness recovery procedure is described for the PI observer-based controller design which asymptotically achieves the same loop transfer functions as the full-state feedback control implementation. A design example is included and the effectiveness of our method is illustrated by simulation results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kailath, T. (1980) · Cited by 6,215
IEEE Transactions on Automatic Control
(2023) · IEEE Transactions on Automatic Control · doi:10.1109/tac.9 · Cited by 2,649
Design of proportional-integral observer for linear time-varying multivariable systems
Shafai, B., & Carroll, R. (1985) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.1985.268557 · Cited by 58
Self-citation
Cited by
The State of Charge Estimation of Lithium-Ion Batteries Based on a Proportional-Integral Observer
Xu, J., Mi, C. C., Cao, B., Deng, J., Chen, Z., & Li, S. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2013.2287375 · Cited by 367
“It means that the battery model is observable under any operation condition; thus, it is possible to estimate the internal states of the Li-ion batteries.”
BackgroundState estimation of dynamical systems with nonlinearities by using proportional-integral observer
SÖFFKER, D., YU, T.-J., & MÜLLER, P. C. (1995) · International Journal of Systems Science · doi:10.1080/00207729508929120 · Cited by 216
Observer design for continuous-time dynamical systems
Bernard, P., Andrieu, V., & Astolfi, D. (2022) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2021.11.002 · Cited by 186
“A well-known example of such an approach is the so-called Proportional-Integral Ob-server (PI-observer) in which both the output estimation error and its integral are typically employed in the observer design, enlightening remarkable improvements, see, e.g., [43, 176, 70].”
BackgroundApplying discrete-time proportional Integral observers for state and disturbance estimations
Chang, J.-L. (2006) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2006.875019 · Cited by 167
Metadata
- Authors
- BEALE, S., & SHAFAI, B.
- Venue
- International Journal of Control
- Publisher
- Informa UK Limited
- Published
- 1989-07
- Volume
- 50
- Issue
- 1
- Pages
- 97-111
- ISSN
- 0020-7179 (ISSN-L)
- 1366-5820
- OpenAlex
- W2149065404
- Cited by
- 165
- References
- 3
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.