An analytic structure factor for macroion solutions
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We assume the time-averaged structure of a macroion solution to be determined only by the repulsive screened Coulomb pair potential between finite macroions. The counter ions and solvent are treated as a uniform neutralizing background which determines the screening of the potential. We slove the Ornstein-Zernike equation in the mean spherical approximation to obtain closed analytic forms for the direct correlation function c(r) and the structure factor S(Q). In the zero charge limit, the Percus-Yevick hard sphere solution is recovered. As charge is added to the macroions at given volume fraction, the isothermal compressibility decreases and S(Q) shows increasing structure, eventually exhibiting solid-like behaviour. The results provide a useful model basis for studying interacting colloidal systems, and finite ion screened one component plasmas in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions
McQuarrie, D. A. (1966) · American Journal of Physics · doi:10.1119/1.1972842 · Cited by 40,433
Analysis of Classical Statistical Mechanics by Means of Collective Coordinates
Percus, J. K., & Yevick, G. J. (1958) · Physical Review · doi:10.1103/physrev.110.1 · Cited by 2,856
Structure and Resistivity of Liquid Metals
Ashcroft, N. W., & Lekner, J. (1966) · Physical Review · doi:10.1103/physrev.145.83 · Cited by 1,252
Statistical mechanics of simple coulomb systems
Baus, M. (1980) · Physics Reports · doi:10.1016/0370-1573(80)90022-8 · Cited by 751
Cited by
Pedersen, J. S. (1997) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(97)00312-6 · Cited by 1,653
Irena: tool suite for modeling and analysis of small-angle scattering
Ilavsky, J., & Jemian, P. R. (2009) · Journal of Applied Crystallography · doi:10.1107/s0021889809002222 · Cited by 1,612
Analysis of small angle neutron scattering spectra from polydisperse interacting colloids
Kotlarchyk, M., & Chen, S.-H. (1983) · The Journal of Chemical Physics · doi:10.1063/1.446055 · Cited by 997
A rescaled MSA structure factor for dilute charged colloidal dispersions
Hansen, J.-P., & Hayter, J. B. (1982) · Molecular Physics · doi:10.1080/00268978200101471 · Cited by 800
Self-citationPhase diagram and dynamics of Yukawa systems
Robbins, M. O., Kremer, K., & Grest, G. S. (1988) · The Journal of Chemical Physics · doi:10.1063/1.453924 · Cited by 657
Metadata
- Authors
- Hayter, J. B., & Penfold, J.
- Venue
- Molecular Physics
- Publisher
- Informa UK Limited
- Published
- 1981-01
- Volume
- 42
- Issue
- 1
- Pages
- 109-118
- ISSN
- 0026-8976 (ISSN-L)
- 1362-3028
- OpenAlex
- W2024027867
- Cited by
- 1,149
- References
- 4
- FWCI
- 18.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.