Can capillary whole blood glucose and venous plasma glucose measurements be used interchangeably in diagnosis of diabetes mellitus?
Abstract
According to new proposals from the American Diabetes Association (ADA) and WHO, venous peripheral plasma is the preferred system for measuring glucose for diagnosing diabetes mellitus. Owing to the instability of glucose in plasma after blood sampling, strict well-defined and standardized preanalytical conditions are essential to ensure that glucose concentration measured in plasma reflects real blood glucose in the patient. This is in contrast to the capillary whole blood measurements, which are easy to perform and well established. We investigated whether it is possible to perform analysis on capillary whole blood but express the results as plasma glucose values and hence obtain comparable results and the same predictive values for diagnosis in the individual patient? The conclusion of our investigations is that these two systems are not interchangeable and that conversion should not be done for diagnostic purposes where plasma determinations are recommended.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Capillary and venous plasma glucose concentrations differ and are not interchangeable, and conversion factors do not accurately estimate equivalent values (46).”
From International Association of Diabetes and Pregnancy Study Groups Recommendations on the Diagnosis and Classification of Hyperglycemia in Pregnancy (2010) · cites this paper as [46]
Citations
Cites
Die enzymatische Bestimmung von Glucose und Fructose nebeneinander
Schmidt, F. H. (1961) · Klinische Wochenschrift · doi:10.1007/bf01506150 · Cited by 503
Eine Glucose-Dehydrogenase für die Glucose-Bestimmung in Körperflüssigkeiten
Banauch, D., Brümmer, W., Ebeling, W., Metz, H., Rindfrey, H., Lang, H., Leybold, K., & Rick, W. (1975) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1975.13.3.101 · Cited by 118
Proposal for standardizing direct-reading biosensors for blood glucose
Fogh‐Andersen, N., & D’Orazio, P. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.655 · Cited by 88
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79
Whole Blood Glucose: What are We Actually Measuring?
Wiener, K. (1995) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329503200101 · Cited by 61
The difference between the glucose concentrations in plasma and whole blood
Holtkamp, H. C., Verhoef, N. J., & Leijnse, B. (1975) · Clinica Chimica Acta · doi:10.1016/0009-8981(75)90216-8 · Cited by 51
Blood glucose: Its measurement and clinical importance
Marks, V. (1996) · Clinica Chimica Acta · doi:10.1016/0009-8981(96)06330-9 · Cited by 50
P. Hyltoft Petersen, I. B. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133630 · Cited by 49
Kokholm, G. (1990) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519009087494 · Cited by 38
Quality assessment of blood glucose testing in general practitioners’ offices improves quality
Stahl, M., Brandslund, I., Iversen, S., & Filtenborg, J. A. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.10.1926 · Cited by 18
Self-citation
Cited by
International Association of Diabetes and Pregnancy Study Groups Consensus Panel (2010) · Diabetes Care · doi:10.2337/dc09-1848 · Cited by 5,390
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
D'Orazio, P. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051979 · Cited by 208
Serum 1,5-Anhydroglucitol (GlycoMark™): A Short-Term Glycemic Marker
Buse, J. B., Freeman, J. L. R., Edelman, S. V., Jovanovic, L., & McGill, J. B. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503765691839 · Cited by 187
Metadata
- Authors
- Stahl, M., Brandslund, I., Jørgensen, L. G. M., Petersen, P. H., Borch-Johnsen, K., & Olivarius, N. D. F.
- Affiliations
- Odense University Hospital (DK)
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 62
- Issue
- 2
- Pages
- 159-166
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1994488021
- Cited by
- 50
- References
- 11
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 3 · 2016: 3 · 2015: 2 · 2013: 2 · 2012: 2
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
- Keywords
- diabetes diagnosis, venous plasma glucose, method interchangeability, diagnostic accuracy
- MeSH terms
- Algorithms, Blood, Blood Glucose, Capillaries, Chemistry, Clinical, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Humans, Plasma, Veins, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can capillary whole blood glucose and venous plasma glucose measurements be used interchangeably in diagnosis of diabetes mellitus? https://app.cochat.ai/papers/10.1080/003655102753611799
- The paper
- Stahl, M., Brandslund, I., Jørgensen, L. G. M., Petersen, P. H., Borch-Johnsen, K., & Olivarius, N. D. F. (2002). Can capillary whole blood glucose and venous plasma glucose measurements be used interchangeably in diagnosis of diabetes mellitus? Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/003655102753611799
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.