Biological variation and reference change values of CA 19‐9, CEA, AFP in serum of healthy individuals
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The use of tumour markers in diagnosis and monitoring is very common. Tumour marker results vary - preanalytical sources of variation, total random analytical error (CV(a)), and within-subject (intraindividual) normal biological variation. There are not so many studies evaluating the biological variations and reference change values (RCV) of these parameters. The aim of our study was to assess: (i) the average inherent intra- and inter-individual biological variation (CV(i) and CV(g)) for CA 19-9, CEA, AFP in a group of healthy individuals; (ii) the significance of changes in serial results of each marker; and (iii) the index of individuality. MATERIAL AND METHODS: The study group comprised 49 healthy volunteers ranging in age between 18 and 60 years (25 M and 24 F). Four blood samples were obtained from each subject; one at each 14-day interval. Each sample from one individual was assayed in duplicate. CA 19-9, CEA, AFP levels were measured by an immunoluminometric assay on a random-access analyser (Architect i2000; Abbott Diagnostics Division). The intra- (CV(i)) and inter-individual (CV(g)) biological variations were estimated from the data generated. Reference change value (RCV) was calculated. RESULTS: The intra-individual/inter-individual biological variations (CVs) for CA 19-9, CEA, AFP were 27.2/64.24 %, 30.87/37.14 % and 26.67/43.65 %, respectively. The critical differences (RCVs) of CA 19-9, CEA, AFP were 64.71 %, 72.57 % and 62.62 %, respectively (Z = 1.65 for unidirectional changes; p<0.05). CONCLUSIONS: Intra-individual biological variation contributes to the variation in serial results and should therefore be included in the criteria for serum tumour marker assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trapé, J., Botargues, J. M., Porta, F., Ricós, C., Badal, J. M., Salinas, R., Sala, M., & Roca, A. (2003) · Clinical Chemistry · doi:10.1373/49.7.1209 · Cited by 30 · cited 1×
“However, the CVi (12 %) differed with our CVg (26 %) [31].”
Background
Cited by
Relational Stability in the Expression of Normality, Variation, and Control of Thyroid Function
Hoermann, R., Midgley, J. E. M., Larisch, R., & Dietrich, J. W. (2016) · Frontiers in Endocrinology · doi:10.3389/fendo.2016.00142 · Cited by 48
Critical review and meta-analysis of biological variation estimates for tumor markers
Marques-Garcia, F., Boned, B., González-Lao, E., Braga, F., Carobene, A., Coskun, A., Díaz-Garzón, J., Fernández-Calle, P., Perich, M. C., Simon, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0725 · Cited by 24
Wannhoff, A., Brune, M., Knierim, J., Weiss, K. H., Rupp, C., & Gotthardt, D. N. (2019) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.15146 · Cited by 17
Metadata
- Authors
- Erden, G., Barazi, A. O., Tezcan, G., & Yildirimkaya, M. M.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 68
- Issue
- 3
- Pages
- 212-218
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2003165086
- Cited by
- 42
- References
- 1
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biological variation and reference change values of CA 19‐9, CEA, AFP in serum of healthy individuals. https://app.cochat.ai/papers/10.1080/00365510701601699
- The paper
- Erden, G., Barazi, A. O., Tezcan, G., & Yildirimkaya, M. M. (2008). Biological variation and reference change values of CA 19‐9, CEA, AFP in serum of healthy individuals. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365510701601699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.