The DOI matches its Crossref record.
Measured and derived quantities with modern pH and blood gas equipment: Calculation algorithms with 54 equations
Abstract
Modern pH and blood gas equipment, combining electrochemical and optical methods, measures pH, Pco2, po2, hemoglobin concentration, oxygen saturation, carboxy-hemoglobin, and methemoglobin. Measurements in arterial and mixed venous blood and in expired air (including measurement of expiratory ventilation) allow calculation of a series of derived quantities: concentrations of bicarbonate, total carbon dioxide, base excess, standard bicarbonate, total oxygen, 2,3-diphosphoglycerate; p50, arteriovenous CO2 and O2 differences, pulmonary shunting, ventilation-perfusion ratio, dead space ventilation, CO2 production, O2 consumption, respiratory quotient, energy metabolism, and cardiac output. Accurate measurement of carboxyhemoglobin even gives an opportunity of measuring blood volume.Equations are reviewed for these calculations including the Henderson-Hasselbalch equation for plasma and whole blood, the Van Slyke equation, the ODC-equation (hyperbolic tangent function), alveolar air equation, Bohr equation, and others. Some of the algorithms have not been previously published. The precision of the calculated quantities is evaluated on the basis of the precision of the measured quantities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diagnosis of Metabolic Acid–Base Disturbances in Critically Ill Patients
FENCL, V., JABOR, A., KAZDA, A., & FIGGE, J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.6.9904099 · Cited by 476
Gender differences in substrate utilization during submaximal exercise in endurance-trained subjects
Roepstorff, C., Steffensen, C. H., Madsen, M., Stallknecht, B., Kanstrup, I.-L., Richter, E. A., & Kiens, B. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00266.2001 · Cited by 279
Helge, J. W., Watt, P. W., Richter, E. A., Rennie, M. J., & Kiens, B. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.01009.x · Cited by 158
Metadata
- Authors
- Siggaard-Andersen, O., Wimberley, P. D., Fogh-Andersen, N., & Gøthgen, I. H.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1988-01
- Volume
- 48
- Issue
- sup189
- Pages
- 7-15
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2009321007
- Cited by
- 164
- References
- 0
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measured and derived quantities with modern pH and blood gas equipment: Calculation algorithms with 54 equations. https://app.cochat.ai/papers/10.1080/00365518809168181
- The paper
- Siggaard-Andersen, O., Wimberley, P. D., Fogh-Andersen, N., & Gøthgen, I. H. (1988). Measured and derived quantities with modern pH and blood gas equipment: Calculation algorithms with 54 equations. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365518809168181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.