Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record.

Development of a novel, N-Terminal-proBNP (NT-proBNP) assay with a low detection limit

Karl, J., Borgya, A., Gallusser, A., Huber, E., Krueger, K., Rollinger, W., Schenk, J. · 1999 · Scandinavian Journal of Clinical and Laboratory Investigation

Abstract

A novel, highly sensitive and specific N-Terminal-proBNP (NT-proBNP) assay based on a sandwich format has been developed. The assay time is below 2 hours and no extraction process is needed. The calibration curve covers a NT-proBNP concentration range from 0 pmol/L up to 600 pmol/L. The analytical detection limit of the assay was estimated to be 2.7 pmol/L (3 SD). The intra-assay coefficient of variation is 5.7% (at 50 pmol/L) and 6.1% (at 250 pmol/L), while the inter-assay CVs are 15.8% (15 pmol/L) and 8.2% (250 pmol/L). There is no significant interference by bilirubin (up to 900 mumol/L), haemoglobin (up to 10 g/L), rheumatoid factors (up to 975 IU/mL), triglycerides (up to 20.5 mmol/L), biotin (up to 50 micrograms/L), digoxin (up to 100 micrograms/L) and digitoxin (up to 200 micrograms/L). The analyte NT-proBNP is fully stable in whole blood over 3 days and in EDTA-plasma over 24 hours. This good stability of NT-proBNP compared to other less stable natriuretic peptides is a significant advantage and a main prerequisite for a routine diagnostic marker. Preliminary results of using this new assay in clinical studies for diagnosing and monitoring left ventricular dysfunction demonstrate that there is a significant gain in diagnostic validity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365519909168341

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 6

  1. Cowie M, 1997, Lancet, 350, 1349, 10.1016/S0140-6736(97)06031-5 · DOI · Paper page
  2. Daggubati S, 1997, Cardiovascular Research, 36, 246, 10.1016/S0008-6363(97)00164-8 · DOI
  3. Hunt P, 1997, Clinical Endocrinology, 47, 287, 10.1046/j.1365-2265.1997.2361058.x · doi:10.1046/j.1365-2265.1997.2361058.x
  4. Cleland J, 1996, Heart, 75, 410, 10.1136/hrt.75.4.410 · doi:10.1136/hrt.75.4.410
  5. Masuta K, 1998, Clin Chem, 44, A 130
  6. Glick M., 1986, Clin Chem, 32, 470, 10.1093/clinchem/32.3.470 · DOI · Paper page

Cited by

See all 182

Metadata

Authors
Karl, J., Borgya, A., Gallusser, A., Huber, E., Krueger, K., Rollinger, W., & Schenk, J.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
1999-01
Volume
59
Issue
sup230
Pages
177-181
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2134964824
Cited by
182
References
0
FWCI
3.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a novel, N-Terminal-proBNP (NT-proBNP) assay with a low detection limit. https://app.cochat.ai/papers/10.1080/00365519909168341
The paper
Karl, J., Borgya, A., Gallusser, A., Huber, E., Krueger, K., Rollinger, W., & Schenk, J. (1999). Development of a novel, N-Terminal-proBNP (NT-proBNP) assay with a low detection limit. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365519909168341

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.