Gastric Emptying: Comparison of Scintigraphic, Polyethylene Glycol Dilution, and Paracetamol Tracer Assessment Techniques
The DOI matches its Crossref record.
Abstract
BACKGROUND: The method of choice for studying gastric emptying is dependent on several factors. The aim of the present study was to assess the concordance between solid gastric emptying, using a scintigraphic technique as gold standard, and gastric emptying as measured with parcetamol tracer and polyethylene glycol (PEG) dilution. METHODS: Two groups of seven male volunteers with similar ages and weights were studied, one for scintigraphic (310-kcal omelette with 12-15 MBq 99mTc-labeled macroaggregated albumin) and paracetamol (1.5 g dissolved in water and administered concomitantly with the omelette) and one for the marker dilution study (PEG 4000 dissolved in a 310-kcal meal). RESULTS: The gastric half-emptying time (T50) was shorter in the PEG study than in the scintigraphic test (47.5 (37.5-62) versus 68.1 (43.6-89.4), median (range) (P < 0.05), respectively), whereas there was no significant difference between the T50 for gastric emptying as assessed with the scintigraphic and paracetamol tracer methods. No difference in gastric emptying rate using PEG dilution or paracetamol tracer was obtained. CONCLUSIONS: In summary, this study shows that scintigraphic, paracetamol tracer, and PEG dilution methods can all be used to assess gastric emptying. The use of the paracetamol tracer technique offers a relatively inexpensive technique that yields a good approximation of gastric emptying as verified by the scintigraphic emptying of a solid meal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Verdich, C., Flint, A., Gutzwiller, J.-P., Näslund, E., Beglinger, C., Hellström, P. M., Long, S. J., Morgan, L. M., Holst, J. J., & Astrup, A. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.9.7877 · Cited by 600
The influence of emulsion structure and stability on lipid digestion
Golding, M., & Wooster, T. J. (2010) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2009.11.006 · Cited by 592
Sex Differences in Pharmacokinetics and Pharmacodynamics
Gandhi, M., Aweeka, F., Greenblatt, R. M., & Blaschke, T. F. (2004) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.44.101802.121453 · Cited by 542
Ultrasound assessment of gastric content and volume
Van de Putte, P., & Perlas, A. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu151 · Cited by 482
Ultrasound Assessment of Gastric Content and Volume
Perlas, A., Chan, V. W. S., Lupu, C. M., Mitsakakis, N., & Hanbidge, A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181a97250 · Cited by 451
Metadata
- Authors
- Näslund, E.
- Venue
- Scandinavian Journal of Gastroenterology
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 35
- Issue
- 4
- Pages
- 375-379
- ISSN
- 0036-5521 (ISSN-L)
- 1502-7708
- OpenAlex
- W1977840648
- Cited by
- 110
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gastric Emptying: Comparison of Scintigraphic, Polyethylene Glycol Dilution, and Paracetamol Tracer Assessment Techniques. https://app.cochat.ai/papers/10.1080/003655200750023930
- The paper
- Näslund, E. (2000). Gastric Emptying: Comparison of Scintigraphic, Polyethylene Glycol Dilution, and Paracetamol Tracer Assessment Techniques. Scandinavian Journal of Gastroenterology. https://doi.org/10.1080/003655200750023930
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.