Determining ‘true’ glomerular filtration rate in healthy adults using infusion of inulin and comparing it with values obtained using other clearance techniques or prediction equations
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine 'true' glomerular filtration rate (GFR) in healthy adults as renal clearance following infusion of inulin, and compare that result with those obtained using other markers and clearance techniques and with estimations of GFR using creatinine-based prediction equations. MATERIAL AND METHODS: Twenty healthy volunteers (11 females) with a median age of 27 years (range 19-36 years) received bolus doses of inulin and iohexol i.v. and 16 blood samples were taken after injection. Then, inulin and iohexol were infused to give stable plasma concentrations and blood and urine samples were collected. Residual bladder volume was estimated using ultrasound scanning. Plasma and urine concentrations of inulin and iohexol were determined using chromatography and resorcinol methods, respectively. Different methods of GFR determination were compared as well as four formulae for GFR estimation based on serum creatinine. RESULTS: 'True' GFR, i.e. renal clearance of inulin during its infusion, was a median of 117 ml/min/1.73 m2 (inter-quartile range 106-129 ml/min/1.73 m2). Similar values of GFR were obtained with renal clearance of iohexol during its infusion and also with plasma (body) clearance of inulin or iohexol following bolus injections and using 16 or five plasma samples. Endogenous creatinine clearance was higher (p<0.001) than true GFR (median 23 ml/min/1.73 m2). Plasma clearance of iohexol and inulin based on their concentrations in four blood samples underestimated their renal clearance considerably. All four creatinine-based formulae markedly underestimated renal inulin clearance. CONCLUSIONS: Plasma and renal clearance of iohexol and inulin were similar in healthy adults. Underestimation of GFR was noted when plasma clearance of iohexol and inulin was based on four but not five or more blood samples. Some prediction equations underestimate true GFR to such an extent that caution must be taken when using them to evaluate normal or high GFR values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952 · cited 3×
“Moreover, when GFR is normal or supernormal the GFR prediction equations are less accurate and have been shown to markedly underestimate GFR [10].”
BackgroundInfluential
Cited by
Measuring GFR: A Systematic Review
Soveri, I., Berg, U. B., Björk, J., Elinder, C.-G., Grubb, A., Mejare, I., Sterner, G., & Bäck, S.-E. (2014) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2014.04.010 · Cited by 491
Self-citationDeFronzo, R. A., Hompesch, M., Kasichayanula, S., Liu, X., Hong, Y., Pfister, M., Morrow, L. A., Leslie, B. R., Boulton, D. W., Ching, A., et al. (2013) · Diabetes Care · doi:10.2337/dc13-0387 · Cited by 293
“A bolus of iohexol providing 45 mg organic iodine followed by a continuous infusion delivering 15 mg/h organic iodine (22) was initiated ;1 h before the SHC to assess GFR.”
MethodEstimated GFR: time for a critical appraisal
Porrini, E., Ruggenenti, P., Luis-Lima, S., Carrara, F., Jiménez, A., de Vries, A. P. J., Torres, A., Gaspari, F., & Remuzzi, G. (2019) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0080-9 · Cited by 294
Delanaye, P., Ebert, N., Melsom, T., Gaspari, F., Mariat, C., Cavalier, E., Björk, J., Christensson, A., Nyman, U., Porrini, E., et al. (2016) · Clinical Kidney Journal · doi:10.1093/ckj/sfw070 · Cited by 233
Self-citationDelanaye, P., Melsom, T., Ebert, N., Bäck, S.-E., Mariat, C., Cavalier, E., Björk, J., Christensson, A., Nyman, U., Porrini, E., et al. (2016) · Clinical Kidney Journal · doi:10.1093/ckj/sfw071 · Cited by 220
Self-citation
Metadata
- Authors
- Sterner, G., Frennby, B., Mansson, S., Nyman, U., Van Westen, D., & Almén, T.
- Venue
- Scandinavian Journal of Urology and Nephrology
- Publisher
- Informa UK Limited
- Published
- 2008-01-01
- Volume
- 42
- Issue
- 3
- Pages
- 278-285
- ISSN
- 0036-5599 (ISSN-L)
- 1651-2065
- OpenAlex
- W2015217576
- Cited by
- 96
- References
- 1
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determining ‘true’ glomerular filtration rate in healthy adults using infusion of inulin and comparing it with values obtained using other clearance techniques or prediction equations. https://app.cochat.ai/papers/10.1080/00365590701701806
- The paper
- Sterner, G., Frennby, B., Mansson, S., Nyman, U., Van Westen, D., & Almén, T. (2008). Determining ‘true’ glomerular filtration rate in healthy adults using infusion of inulin and comparing it with values obtained using other clearance techniques or prediction equations. Scandinavian Journal of Urology and Nephrology. https://doi.org/10.1080/00365590701701806
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.