The DOI matches its Crossref record.
Using national input/output data for embodied energy analysis of individual residential buildings
Open accessAbstract
Embodied energy (EE) analysis has become an important area of energy research, in attempting to trace the direct and indirect energy requirements of products and services throughout their supply chain. Typically, input-output (I-O) models have been used to calculate EE because they are considered to be comprehensive in their analysis. However, a major deficiency of using I-O models is that they have inherent errors and therefore cannot be reliably applied to individual cases. Thus, there is a need for the ability to disaggregate an I-O model into its most important ‘energy paths’, for the purpose of integrating case-specific data. This paper presents a new hybrid method for conducting EE analyses for individual buildings, which retains the completeness of the I-O model. This new method is demonstrated by application to an Australian residential building. Only 52% of the energy paths derived from the I-O model were substituted using case-specific data. This indicates that previous system boundaries for EE studies of individual residential buildings are less than optimal. It is envisaged that the proposed method will provide construction professionals with more accurate and reliable data for conducting life cycle energy analysis of buildings. Furthermore, by analysing the unmodified energy paths, further data collection can be prioritized effectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
System Boundary Selection in Life-Cycle Inventories Using Hybrid Approaches
Suh, S., Lenzen, M., Treloar, G. J., Hondo, H., Horvath, A., Huppes, G., Jolliet, O., Klann, U., Krewitt, W., Moriguchi, Y., et al. (2004) · Environmental Science & Technology · doi:10.1021/es0263745 · Cited by 1,025
Self-citationIdentification of parameters for embodied energy measurement: A literature review
Dixit, M. K., Fernández-Solís, J. L., Lavy, S., & Culp, C. H. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.02.016 · Cited by 750
Life cycle greenhouse gas emissions and energy analysis of prefabricated reusable building modules
Aye, L., Ngo, T., Crawford, R. H., Gammampila, R., & Mendis, P. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2011.11.049 · Cited by 466
Chastas, P., Theodosiou, T., & Bikas, D. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.040 · Cited by 400
Nässén, J., Holmberg, J., Wadeskog, A., & Nyman, M. (2007) · Energy · doi:10.1016/j.energy.2007.01.002 · Cited by 384
Metadata
- Authors
- Treloar, G. J., Love, P. E. D., & Holt, G. D.
- Venue
- Construction Management and Economics
- Publisher
- Informa UK Limited
- Published
- 2001-01
- Volume
- 19
- Issue
- 1
- Pages
- 49-61
- ISSN
- 0144-6193 (ISSN-L)
- 1466-433X
- OpenAlex
- W2085185452
- Cited by
- 173
- References
- 0
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using national input/output data for embodied energy analysis of individual residential buildings. https://app.cochat.ai/papers/10.1080/014461901452076
- The paper
- Treloar, G. J., Love, P. E. D., & Holt, G. D. (2001). Using national input/output data for embodied energy analysis of individual residential buildings. Construction Management and Economics. https://doi.org/10.1080/014461901452076
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.