Characterizing kidney structures in health and diseases using eosin fluorescence from hematoxylin and eosin stained sections
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
For a long time, hematoxylin and eosin (H&E) staining has been widely used for the diagnosis of many diseases by assessing the histopathological changes in tissue sections. Eosin, one of the staining dyes in the H&E stain, is fluorescent in the fluorescein isothiocyanate (FITC) and Texas Red (TxR) fluorescent channels. In this study, the use of eosin fluorescence to visualize and quantify histopathological changes was elucidated in a glycerol-induced model of acute kidney injury (AKI) in mice. AKI was induced in BALB/c mice by intramuscularly injecting 10 mL/kg of 50% glycerol after 24 h of water deprivation and, after another 24 h, the kidneys were dissected out. After H&E staining, kidney tissue sections were examined under a fluorescent microscope using a double-channel filter cube (FITC and TxR). The H&E fluorescence pattern of normal kidney structures was characterized as the fluorescence patterns varied between different parts of the kidney and could be used for the structural identification of different parts of the kidney. Interestingly, in the injured kidney sections, a striking increase in the red fluorescence was noticed only in the damaged areas. In the damaged kidney sections, casts deposited inside tubules showed bright yellow fluorescence, whereas fibers showed strong green fluorescence. In vitro experiments were also performed in order to understand possible mechanisms underlying this phenomenon. It was concluded that eosin fluorescence can be used to quantify the degree of damage to kidney tissue which, in turn, may help in assessing the kidney-protective effects of unknown compounds and plant extracts.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“FFPE preservation and H&E staining are part of the standard of care tissue processing in clinical pathology settings but are also known to contribute potentially significant fluorescence in some imaging applications.31–34”
From Assessment of unmixing approaches for the quantitation of SERS nanoparticles in highly multiplexed spectral images (2024) · cites this paper as [31]
Citations
Cites
Histotechnology: A Self-Instructional Text
Carson, F. L. (1990) · Medical Entomology and Zoology · Cited by 560
Animal models of acute renal failure
Singh, A. P., Muthuraman, A., Jaggi, A. S., Singh, N., Grover, K., & Dhawan, R. (2012) · Pharmacological Reports · doi:10.1016/s1734-1140(12)70728-4 · Cited by 266
HISTOCHEMICAL USES OF HAEMATOXYLIN - A REVIEW
Avwioro, G. O. (2011) · Cited by 112
Kim, J. H., Lee, S. S., Jung, M. H., Yeo, H. D., Kim, H. J., Yang, J. I., Roh, G. S., Chang, S. H., & Park, D. J. (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp659 · Cited by 107
Nuclear staining with alum hematoxylin
Llewellyn, B. (2009) · Biotechnic & Histochemistry · doi:10.1080/10520290903052899 · Cited by 105
Carvalho, H. F., & Taboga, S. R. (1996) · Histochemistry and Cell Biology · doi:10.1007/bf02473274 · Cited by 74
Chadwick, C. S., McEntegart, M. G., & Nairn, R. C. (1958) · PubMed · Cited by 69
ROSSI, A. D., Rocha, L. B., & Rossi, M. A. (2007) · Journal of Oral Pathology and Medicine · doi:10.1111/j.1600-0714.2007.00542.x · Cited by 56
The mechanism of action of ?mordant? dyes ? a study using preformed metal complexes
Marshall, P. N., & Horobin, R. W. (1973) · Histochemistry and Cell Biology · doi:10.1007/bf00310675 · Cited by 39
Characterizing Cutaneous Elastic Fibers by Eosin Fluorescence Detected by Fluorescence Microscopy
Heo, Y. S., & Song, H. J. (2011) · Annals of Dermatology · doi:10.5021/ad.2011.23.1.44 · Cited by 30
Fluorescence of hematoxylin and eosin-stained histological sections of the human spleen
Jakubovský, J., Guller, L., Černá, M., Balážová, K., Polák, Š., Jakubovská, & Babál, P. (2002) · Acta Histochemica · doi:10.1078/0065-1281-00684 · Cited by 28
Fluorescence microscopy in the detection of early myocardial infarction
Badir, B. F., & Knight, B. (1987) · Forensic Science International · doi:10.1016/0379-0738(87)90088-0 · Cited by 28
Lev, R., & Stoward, P. J. (1969) · Histochemistry and Cell Biology · doi:10.1007/bf00263753 · Cited by 13
McMahon, J. T., Myles, J. L., & Tubbs, R. R. (2002) · Modern Pathology · doi:10.1097/01.mp.0000027202.51385.85 · Cited by 11
Evaluation of eosin-fluorescence in the diagnosis of sudden cardiac death
Saukko, P. J., & Knight, B. (1989) · Forensic Science International · doi:10.1016/0379-0738(89)90187-4 · Cited by 10
Alpha-1-antitrypsin Hematoxylin and Eosin Fluorescence: A Rapid, Useful Screening Technic
Dervan, P. A. (1984) · American Journal of Clinical Pathology · doi:10.1093/ajcp/82.2.188 · Cited by 9
Eosin-related fluorescence of acidophil pituitary cells.
Friedman, H., Friedman, I. V. C., & Mello, C. V. (1988) · PubMed · Cited by 2
Research works printed but not linked: 4
- Avwioro G, 2011, J Pharm Clin Sci, 1, 24
- Chadwick C, 1958, Immunol, 1, 315
- Friedman H, 1988, Histol Histopath, 3, 223
- 10.1016/0379-0738(89)90187-4 · DOI
Cited by
Ren, Y., Zhou, Q., Xu, Y., Xu, B., Shu, P., & Peng, L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202402836 · Cited by 12
Czaja, A., Awad, S., Eremina, O. E., Fernando, A., & Zavaleta, C. (2024) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6653 · Cited by 8
Lv, L., Wang, X., Wu, H., Tang, J., Dong, X., Li, Z., Yu, J., & Guan, Q. (2025) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2025.144219 · Cited by 5
Jo, H., Kim, J., Kim, J., Kim, B., Choi, B. Y., Kang, K., Ryu, J., & Kim, M. S. (2023) · Clinical and Translational Science · doi:10.1111/cts.13528 · Cited by 4
Nuclear and cytoplasmic remodeling of ectocervical cells by high activity of gelsolin
Farkas, B., Szatmári, Z., Kovács, K., Kovács, K. A., Bárdos, N., Türmer, K., Kovács, O. M., Czimbalek, L., & Szatmári, D. (2025) · Scientific Reports · doi:10.1038/s41598-025-20822-z · Cited by 1
“Siddiqui et al. found that eosin fluorescence helps to distinguish renal structures and cells in healthy and diseased states, as protein denaturation, necrosis and fibrosis can be easily identified with more detail than classical histopathologic methods 49 .”
Influential
Metadata
- Authors
- Siddiqui, R. A., Kabir, N., Ateeq, M., Simjee, S. U., & Raza Shah, M.
- Affiliations
- University of Karachi (PK)
- University of Malaya (MY)
- HEJ Research Institute of Chemistry, International Center for Chemical and Biological Science, University of Karachi, Karachi, Pakistan
- Corresponding author
- Kabir, Nurul
- Venue
- Journal of Histotechnology
- Publisher
- Informa UK Limited
- Published
- 2016-10
- Volume
- 39
- Issue
- 4
- Pages
- 107-115
- ISSN
- 0147-8885 (ISSN-L)
- 2046-0236
- OpenAlex
- W2565052072
- Cited by
- 7
- References
- 17
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Histotechnology (publishedVersion)
- Topics
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Health Sciences › Medicine › Pathology and Forensic Medicine › Biological Stains and Phytochemicals
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- H&E staining, acute kidney injury, kidney histopathology, plant extracts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.